6
C L I M A T E M A S T E R W A T E R - S O U R C E H E A T P U M P S
Tr a n q u i l i t y
®
( T R ) S e r i e s
R e v. : N o v e m b e r 2 , 2 0 2 0
C l i m a t e M a s t e r Wa t e r - S o u r c e H e a t P u m p s
TR Series
006
009
012
015
018
024
030
036
042
048
060
Compressor (1 each)
Rotary
Scroll
Factory Charge HFC-410A
- (oz.)
19
20
23
35
43
40
48
50
70
74
82
ECM Fan Motor & Blower
Blower Wheel Size (Dia x w)
6x5
6x5
6x5
9x7
9x7
9x7
9x7
9x8
9x8
10x10
11x10
PSC Fan Motor & Blower
Fan Motor Type/Speeds
PSC/3 PSC/3 PSC/3
PSC/3
PSC/3
PSC/3
PSC/3
PSC/3
PSC/3
PSC/3
PSC/3
Blower Wheel Size (Dia x W)
5x5
5x5
6x5
8x7
8x7
9x7
9x7
9x8
9x8
10x10
11x10
Water Connection Size
Source FPT
1/2”
1/2”
1/2”
1/2”
1/2”
3/4”
3/4”
3/4”
3/4”
1”
1”
Optional HWG FPT
1/2”
Coax Volume (gallons)
0.123
0.143
0.167
0.286
0.45
0.286
0.323
0.323
0.89
0.738
0.939
Vertical
Air Coil Dimensions (H x W)
10x15 10x15 10x15
20x17.25
20x17.25
20x17.25
20x17.25
24x21.75
24x21.76
28x25
28x25
Filter Standard - 1”
Throwaway
10x18 10x18 10x18
20x20
20x20
20x20
20x20
24x24
24x24
28x28
28x28
Weight - Operating (lbs.)
110
112
121
163
168
184
192
213
228
283
298
Weight - Packaged (lbs.)
115
117
126
168
173
189
197
219
234
290
305
Horizontal
Air Coil Dimensions (H x W)
10x15 10x15 10x15
16x22
16x22
16x22
16x22
20x25
20x25
20x35
20x35
Filter Standard - 1”
Throwaway
10x18 10x18 10x18
16x25
16x25
18x25
18x25
20x28 or
2-20x14
20x28 or
2-20x14
1-20x24,
1-20x14
1-20x24,
1-20x14
Weight - Operating (lbs.)
110
112
121
163
168
184
192
213
228
283
298
Weight - Packaged (lbs.)
115
117
126
168
173
189
197
219
234
290
305
Notes: All units have TXV expansion device and 1/2” & 3/4” electrical knockouts.
575 volt fan motors are two speed.
FPT=Female Pipe Thread
Condensate Drain Connection is 3/4” FPT.
For ClimaDry
®
option add 30 lbs (13.6 kg).
Unit Maximum Water Working Pressure
Options
Max Pressure PSIG [kPa]
Base Unit
500 [3447]
Internal Secondary Pump (ISP)
145 [999]
Internal Motorized Water Valve (MWV)
300 [2,068]
Internal Auto Flow Valve
300 [2,068]
ClimaDry
®
145 [999]
Use the lowest maximum pressure rating when multiple options are combined.
Unit Physical Data
Tranquility
®
(TR) Series (60 Hz)
Summary of Contents for Tranquility TR Series