background image

OPERATION MANUAL

 

20

 

 

 

 

Limited Warranty

 

 

ClimaTemp Portables Inc. warrants its portable air conditioner products and accessories against defects 

in material or workmanship. Under ordinary use ClimaTemp will, at its sole discretion, repair or replace 

any defective product or part covered by this warranty. Warranty coverage is (12) months for all parts on 

the ClimaTemp product and (36) months on the compressor or compressor components. This warranty is 

in effect from the date of purchase on any invoicing for the end user. This Limited warranty is conditional 

on the return of the part or unit to the manufacturer with approval in which all goods and services are 

freight prepaid from the customer or distributor. This warranty does not cover malfunctions or misuse 
beyond ClimaTemp’s control including improper operation, neglect, abuse, abnormal use, incorrect 

electrical connections, and failure to perform routine maintenance. Furthermore, ClimaTemp will not be 

responsible for improper installation that damages unit or components. Any shipping damage or improper 

transport is not covered under this warranty. All other products are covered by a full 1 year warranty 

where applicable. 

 

DISCLAIMER OF WARRNTY EXCEPT AS EXPRESSLY PROVIDED IN THIS STANDARD WARRANTY POLICY STATEMENT, 

CLIMATEMP PORTABLES HEREBY EXPRESSLY DISCLAIMS ALL REPRESENTATIONS, CONDITIONS AND WARRANTIES, WHETHER 

EXPRESS OR IMPLIED, INCLUDING BY WAY OF EXAMPLE AND NOT LIMITATION, THE IMPLIED WARRANTIES OF TITLE, 

MERCHANTABILITY, NONINFRINGEMENT AND FITNESS FOR A PARTICULAR PURPOSE. LIMITATION ON LIABILITY 

NOTWITHSTANDING ANYTHING HEREIN TO THE CONTRARY, IN NO EVENT WILL CLIMATEMP PORTABLES BE LIABLE FOR ANY 

SPECIAL, INCIDENTAL, PUNITIVE OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDING LOSS OF PROFITS, WHETHER 

ARISING IN CONTRACT, TORT, WARRANTY OR OTHERWISE, EVEN IF IT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH 

DAMAGES. THE LIMITATIONS SET FORTH HERE WILL APPLY EVEN IF THE REMEDIES OF ERROR CORRECTION, REPAIR OR 

REPLACEMENT, REPERFORMANCE OF SERVICES AND REFUND OF PAYMENTS COMPLETELY FAIL OF THEIR ESSENTIAL 

PURPOSE. NOTWITHSTANDING ANYTHING HEREIN TO THE CONTRARY, THE LIMIT OF CLIMATEMP PORTABLES (WHETHER IN 

CONTRACT, TORT, NEGLIGENCE, STRICT LIABILITY, BY STATUTE OR OTHERWISE) TO CUSTOMER OR TO ANY THIRD PARTY 

WITH RESPECT TO WHICH SUCH CLAIM IS MADE. GOVERNING LAW AND JURISDICTION 

 

ClimaTemp Portables Inc. 

844-349-5665 

www.Clima-Temp.com 

Summary of Contents for CPTH-12

Page 1: ...OPERATION MANUAL 1 OPERATION MANUAL CPTH 12 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE AND READ ALL SAFEGUARDS PORTABLE HEAT PUMP...

Page 2: ...OPERATION MANUAL 2 SERIAL NUMBER LOCATION AND IDENTIFICATION The serial number and name plate can be located near the lower right side of the unit Nameplate Label Nameplate Location...

Page 3: ...jams and rough terrain Cord pocket to keep the units power cord organized and out of the way Stylish and functional side bump guards to protect the unit from dents and scratches Features Provides 10 3...

Page 4: ...e Heat Pump 2 Operation Manual 3 Kick Plate Foot Pedal located under the unit Please attach to bottom rear of unit 4 Metal Cord Wrap Holder located under the unit Please attach to back of unit Note If...

Page 5: ...power cable Damage to power cord can cause electric shock or injury Do not place anything on the top of the machine Do not stand or place hands or fingers inside of the unit while in operation Install...

Page 6: ...operation the front and back of the machine should be more than 20 from the wall or other barrier The cold air exhaust should be at least 12 away from any barrier and hot air exhaust should be more th...

Page 7: ...OPERATION MANUAL 7 INSTALLATION cont Moving the Unit Unlock the casters and push the Portable Heat Pump unit using the side handles to a flat level surface and set the casters to the LOCKED position...

Page 8: ...Device The CPTH 12 is equipped with a LCDI power cord This device is non serviceable and opening the device may cause electric shock or void the warranties of the product 1 Plug into grounded appropr...

Page 9: ...ATION MANUAL 9 OPERATION Control Panel Before operating the unit it is important to familiarize yourself with the basic controls located on the control panel Power Run Fan Speed CTHP 12 Portable Heat...

Page 10: ...Power button is on and then press the heating button Press the temperature button the temperature button will start to blink Press the up and down adjustment button on the display to set the temperat...

Page 11: ...protection there will be a 90 second delay when switching from Heat mode to Cool mode while compressor is engaged Note This unit is equipped with state of the art Cold Plasma Needlepoint Bipolar Ioniz...

Page 12: ...ator Unit error When the unit s condensate bucket is full of water or an overcurrent overheat or other trouble is detected by the unit the alarm indicator will turn on When the unit stops working LED...

Page 13: ...P Pressure too high in refrigerant system Surrounding Temperature too high in cooling mode Air exhaust is obstructed Surrounding Temperature to low in heat mode Check and clean filters tc Evaporator...

Page 14: ...to empty the drain tank please wait after the unit stops 1 Open the drain tank door 2 Carefully remove the water tank and do not damage the top components on the top of water tank 3 Empty the drain ta...

Page 15: ...et 2 Mount the condensate pump with the provided screws to the back wall of the rear inside panel Holes are pre drilled and ready for easy installation 3 Attach the pumps wiring harness by aligning th...

Page 16: ...rease in the cooling capacity and damage to the compressor and components Filter Removal Method 1 Turn the unit off by pressing the Power button 2 Remove the two air filters Note To remove the front e...

Page 17: ...gent 2 After the element has been cleaned rinse with clean running water allow to dry then reinstall filters into unit End of Season Maintenance 1 Wrap power cord on rear cord wrap holder 2 Remove all...

Page 18: ...irt particulate are on the front filter Clean the front filter 4 The water level of drain tank is too high Pull out the drain tank and empty it No cooling or heating 1 The surface of the condenser is...

Page 19: ...OPERATION MANUAL 19 Parts List Breakdown...

Page 20: ...ty All other products are covered by a full 1 year warranty where applicable DISCLAIMER OF WARRNTY EXCEPT AS EXPRESSLY PROVIDED IN THIS STANDARD WARRANTY POLICY STATEMENT CLIMATEMP PORTABLES HEREBY EX...

Page 21: ...OPERATION MANUAL 21...

Reviews: