SD-29  series  is  a  mini-sized  wireless  smoke  detector  with  built-in  PIR  motion  sensor,  temperature  sensor  and  emergency  light  (optional). 
Designed  to  protect  your  family  against  potential  fire  hazards,  the  Smoke  detector  is  also  capable  of  detecting  movements  and  reporting 
temperature to users. The Z-Wave

 Smoke Detector 

allows access to the “S2 Unauthenticated” class. 

The SD-29  is  a  wirelessly  operated  photo-electronic Smoke  Detector  designed to  operate  with  any  Z-Wave  enabled  controller  devices;  it  also 
features smoke detecting, temperature sensing and IR detection. The Smoke Detector

’s alarm situations, battery condition, operating conditions, 

supervisory data and general fault information are sent to the Z-Wave Gateway/Control Panel wirelessly. The device is also serially connected 
with other sensors in the Z-Wave gateway to serve as an extra siren. When any other sensor in the Z-Wave network is activated and sends an 
alarm signal, the Smoke Detector will also raise alarm with its built-in buzzer as a siren to help sound warning. 

The SD-29 is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave is a wireless communication protocol 
that uses a low-power RF radio

.

 

The  Smoke  Detector  calibrates  for  the  air  contents  after  warming  up  to  determine  a  standard  condition  for  the  environment.  It  can  also  be 
manually instructed to calibrate for air content. It is also pre-programmed to automatically calibrate once a month. 

The Smoke Detector includes the following models: 

Model Name 

Heat Detection 

Temperature Sensor 

PIR Sensor 

Emergency Light 

Serial Connection 

SD-29-TH-SC 

 

 

SD-29-THM 

 

SD-29-THME 

 

 

P

P

a

a

r

r

t

t

s

s

 

 

I

I

d

d

e

e

n

n

t

t

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

 

 

 

 

 

 

 

 

1.  LED Indicator /Function Button / Emergency Light 

Red LED 

  Turns ON briefly: Transmitting signal. 

  Quick flash: Alarming. 

  Flashes every 1 second: Smoke Detector under Sleep Mode 

  Flashes every 2 seconds: Smoke Detector under warmup and calibration process.   

  Flashes every 4 seconds: battery exhausted. 

Orange LED 

  Flash every second: Device power on/Calibration failed. 

  Flashes every 5 seconds: Detecting smoke failed or device malfunctioning. 

  Flashes every 4 seconds: battery exhausted. 

  Flashes every 45 seconds: Low battery condition 

Function Button 

  Press the button once to send temperature signal to the gateway. 

  Press the button once during alarm to silence the alarm. 

  Press the button twice to discharge before inserting new batteries. 

  Press the button 3 times within 1.5 seconds to send a learn code. 

  Press and hold the button for 10 seconds to enter calibration process. 

  Press and hold the button for 20 seconds to perform factory reset. 

White LED (Emergency Light)

 

  The emergency light will begin to flash slowly to alert uses that the system is alarming. 

(SD-29-THME only)

 

2.  IR Lens 

3.  Buzzer 

4.  Battery Compartment Fixing Screw 

5.  Tamper Switch 

6.  Battery Switch 

Summary of Contents for SD-29-AC-ZW Series

Page 1: ...arming up to determine a standard condition for the environment It can also be manually instructed to calibrate for air content It is also pre programmed to automatically calibrate once a month The Sm...

Page 2: ...beeps 3 times the Optical Chamber on the Smoke Detector is either dirty or out of order T Ta am mp pe er r S Sw wi it tc ch h The SD 29 is protected by a tamper switch which is compressed when the SD...

Page 3: ...ivated by exceeding the second alarm threshold could not be silenced by pressing the Function Button R Re ec ca al li ib br ra at ti io on n As the operation condition of the Smoke Detector may vary a...

Page 4: ...actory reset when network Control Panel Gateway is missing or inoperable Remove the batteries of the Smoke Detector first Press and hold the Function button While holding the Function button power on...

Page 5: ...Step 6 Repeat Step 4 and Step 5 to insert the black wire Inserting the two wires to the same side right as shown below of the the two connectors provides an easier installation in the following steps...

Page 6: ...cific 2 S2 Unauthenticated x Device Reset Locally 1 S2 Unauthenticated x Power Level 1 S2 Unauthenticated x Battery 1 S2 Unauthenticated x Security 2 1 none Notification 8 S2 Unauthenticated x Sensor...

Page 7: ...IFICATION_REPORT Smoke Alarm Triggered 00 00 00 FF 01 02 00 00 Smoke Alarm Restored 00 00 00 FF 01 00 01 02 Smoke Alarm Silenced 00 00 00 FF 01 06 00 Heat Detection Triggered Heat Detection Restored C...

Reviews: