background image

 

 

 

Step 5. 

Repeat Step 3 and Step 4 to insert the black wire. Inserting the two wires to the same side (right), as shown   

 

 

below, of the two connectors provides an easier installation in the following steps. 

Step 6. 

Insert the AC wires to the two connectors respectively, as shown below. Use a pair of tweezers to turn the Battery Switch   
to ON position (left side), the rechargeable battery will begin to charge. 

Figure 3 

Figure 4 

 

 

Step 7.

 Put the Z-Wave gateway or control panel into

 Inclusion

 or 

Learning

 mode (please refer to the Z-Wave gateway or   

control panel manual). 

Step 8. 

.

Within 1.5 seconds, press the Function button 3 times. The Smoke Detector will emit a 2-tone beep and the LED will   

turn on for ~2 seconds. Refer to the operation manual of the Z-Wave gateway or control panel to complete the learn-in   

process. 

  If the sensor  has  already  been 

included

  (learnt)  into  another  Z-Wave  Gateway/Control  Panel,  or  if the  sensor  is  unable  to  be 

learnt into the current Z-Wave Gateway/Control Panel, please exclude it first (see 

Exclusion

) before attempting to 

include

 it into 

the current Z-Wave Gateway/Control Panel. 

 

 

R

R

e

e

m

m

o

o

v

v

i

i

n

n

g

g

 

 

D

D

e

e

v

v

i

i

c

c

e

e

 

 

(

(

E

E

x

x

c

c

l

l

u

u

s

s

i

i

o

o

n

n

)

)

 

 

The  Smoke  Detector  must  be  removed  from  existing  Z-Wave  network  before  being  included  into  another.  There  are  two  methods 
available to exclude a device. 

Exclusion Mode 

  Put the Z-Wave gateway or control panel into 

Exclusion mode

 (please refer to the Z-Wave gateway or control panel manual). 

  Within 1.5 seconds, press the Function button 3 times and the Smoke Detector will be removed from the Z-Wave network. 

Factory Reset 

(Only use factory reset when network Control Panel/Gateway is missing or inoperable).

 

  Remove the batteries of the Smoke Detector first. 

  Press  and  hold  the  Function  button.  While  holding  the  Function  button,  power  on  the  Smoke  Detector  by  re-inserting  the 

batteries, wait for 20 seconds to factory reset. 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

 

Before  you  remove  or  factory  reset  the  Smoke  Detector,  please  ensure  that the  device  DSK  information  has  been  removed  or 
does not exist in the gateway. If you remove or factory reset the device, but its DSK still exists in the gateway, the gateway will 
automatically include the device again.   

 

Factory resetting the Smoke Detector will restore it to factory default settings (excluded from the Z-Wave network). The Z-Wave 
gateway  or  control  panel  will  still  keep  its  Z-Wave  settings.  Please  refer  to  the  gateway  or  control  panel  manual  on  how  to 
remove the Smoke Detector

’s Z-Wave settings. 

 

 

R

R

a

a

n

n

g

g

e

e

 

 

T

T

e

e

s

s

t

t

 

 

 To test whether the device is able to communicate with the Z-Wave gateway or control panel: 

  Put the gateway / panel into range test mode (Walk Test). 

  Press the Function button on the device. 

  The  gateway  /  panel  should  display  if  the  device  is  within  the  operation  range  (please  refer  to  the  operation  manual  of  the 

gateway / panel). 

Installation 

 

 

I

I

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

G

G

u

u

i

i

d

d

e

e

l

l

i

i

n

n

e

e

 

 

  It is recommended that the installation site be in the center area of the ceiling. 

  Do not locate the detector in the following locations: 

 

The Kitchen 

– Smoke from cooking might cause an unwanted alarm. 

 

Near a ventilating fan, florescent lamp or air-conditioning equipment 

– air drafts from them may affect the 

sensitivity of the detector. 

 

Near  ceiling  beams  or  over  a  cabinet 

–  stagnant  air  in  these  areas  may  affect  the  sensitivity  of  the 

detector. 

 

In the peak of an “

A

” frame type of ceiling.

 

 

 

 

Summary of Contents for SD-29-AC-ZW Series

Page 1: ...arming up to determine a standard condition for the environment It can also be manually instructed to calibrate for air content It is also pre programmed to automatically calibrate once a month The Sm...

Page 2: ...beeps 3 times the Optical Chamber on the Smoke Detector is either dirty or out of order T Ta am mp pe er r S Sw wi it tc ch h The SD 29 is protected by a tamper switch which is compressed when the SD...

Page 3: ...ivated by exceeding the second alarm threshold could not be silenced by pressing the Function Button R Re ec ca al li ib br ra at ti io on n As the operation condition of the Smoke Detector may vary a...

Page 4: ...actory reset when network Control Panel Gateway is missing or inoperable Remove the batteries of the Smoke Detector first Press and hold the Function button While holding the Function button power on...

Page 5: ...Step 6 Repeat Step 4 and Step 5 to insert the black wire Inserting the two wires to the same side right as shown below of the the two connectors provides an easier installation in the following steps...

Page 6: ...cific 2 S2 Unauthenticated x Device Reset Locally 1 S2 Unauthenticated x Power Level 1 S2 Unauthenticated x Battery 1 S2 Unauthenticated x Security 2 1 none Notification 8 S2 Unauthenticated x Sensor...

Page 7: ...IFICATION_REPORT Smoke Alarm Triggered 00 00 00 FF 01 02 00 00 Smoke Alarm Restored 00 00 00 FF 01 00 01 02 Smoke Alarm Silenced 00 00 00 FF 01 06 00 Heat Detection Triggered Heat Detection Restored C...

Reviews: