Safety Box Installation: 

When mounting on Safety Box, mount the Sensor no more than 2cm away from the door pivot.   

2.  Clean and dry the mounting location. Do not install on dirty or web surface. 
3.  Use the provided double-sided adhesive tape (

Ø35mm x 8mm

) to apply to the back cover of 

SVGS and stick the sensor onto the mounting location. 

<NOTE> 

 

Please do not apply the double-sided adhesive tape to the front cover where Test Button 
and LED indicator are located, and do not apply the tape twice. 

 

 

Installation Guideline 

 

Always make sure to test detection range after installation to confirm the actual detection range. 

 

The adhesive tape may lose its stickiness over time. Make sure to check the sensor at least once every 6 months. 

 

Avoid mounting at location prone to strong wind that could dislocate the Sensor. 

 

Avoid mounting at location prone to shaking or vibration, which will cause false alarm. 

 

Set the Sensor to low sensitivity when installing on movable windows to prevent false alarming. 

 

Avoid mounting at location where the Sensor could easily collide with object. 

 

When mounting on plywood: 
1  Use only high sensitivity setting. 
2  Mounting on  wall next to large furniture may affect the sensor’s detection range and signal transmission range. 

Make sure to test the sensor if choose to mount at such location. 

 

Sensor  detection  range  is  affected  by  adhesive  tape  size  and  material.  The  sensitivity-range  table  provided  in  this 
document is tested  with factory provided adhesive tape. If different adhesive tape is used, make sure to retest the 
detection range. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 