8. DIP Switch Block
There are 8 DIP Switches for setting the function & detection sensitivity levels.
9. Battery Compartment
10. Mounting Bracket
LED Indicator
When enabled, the LED Indicator will light up in the following conditions:
When the Tamper Switch is triggered, the LED will flash for 6 times to indicate it is transmitting “
Tamper
” signal.
When the PIR Camera is in fault conditions (tamper open or low battery condition persists), each time it transmits a
detected movement, the LED will flash for 6 times.
After the Test button is pressed once to enter Test Mode, the LED will flash for 60 seconds to indicate that the PIR
motion sensor camera is warming up.
In Test mode, the LED will turn on for 2 seconds whenever a movement is detected.
<
<
N
N
O
O
T
T
E
E
>
>
The LED indicator can be enabled by setting the DIP Switch2 to ON position. Please refer to
DIP Switch Position
Table
for details.
Image Capture
When the alarm system is armed, the PIR Camera will capture 1, 3 or 6 alarm images in 640 x 480 or 320 x 240 resolutions
(programmable from Control Panel) upon movement detection. You can also manually request the PIR Camera to take a
picture through the Control Panel. The captured images will be transferred to the Control Panel for visual alarm verification.
Warm Up Period
The PIR Camera will warm up for 60 seconds in the following conditions:
When the PIR Camera is turned on by the Control Panel system upon entering arm mode or entering arm mode with
fault conditions.
When the test button is pressed once to enter Test Mode.
The Red LED will flash slowly during warm up period. During the 60-second warm up period, the PIR Camera will not be
activated.
Test Mode
The PIR Camera can be put into Test mode for 10 minutes by pressing the Test button once. In Test mode, the sleep
timer and image capture functions are disabled. LED indicator is enabled to light up for two seconds whenever a
movement is detected. The PIR Camera will automatically exit Test Mode after 10 minutes, and return to normal mode.
To put the PIR Camera into constant Test mode, please adjust DIP switch1 to ON position (Please refer to
DIP Switch
Position Table
).
Supervision Signal
After installation, the PIR Camera will automatically transmit Supervisory signals periodically to the Control Panel at
random intervals of 15 to 18 minutes.
If the Control Panel has not received the signal from the PIR Camera for the preset period of time, the Control Panel will
indicate on its display that the particular PIR Camera is experiencing an out-of-signal problem.
Sleep Timer
The PIR Camera features an automatic “sleep time” of approximately one minute for power conservation. After
transmitting a detected movement, the PIR Camera will not retransmit for one minute. Any further movement detected
within this one-minute sleep period will extend the sleep time by another minute. This way, continuous movement in
front of PIR Camera will not unduly exhaust the battery.
Double Knock Function
The PIR Camera has a double knock function. If the double knock function is enabled, the PIR Camera will report an
alarm to the control panel only if two movements are detected within 10 seconds. If the double knock function is
disabled, the PIR Camera will report an alarm to the control panel when a movement is detected.
Tamper Protection
The PIR Camera is protected by an internal tamper switch which is compressed when the PIR Camera is hooked onto
the mounting bracket. When the PIR Camera is removed from the mounting bracket, the tamper switch will be activated
and the PIR Camera will send a tamper open signal to the control panel to remind the user of this condition.
Proximity Detection (For 862EX-AM only)
862EX-AM has a digital proximity detector that can detect any masking (blocking) attempt by an intruder.
When a masking event is detected, and the masking condition lasts for 2 minutes, 862EX-AM will send tamper open
signal to the Control Panel to notify user of the condition.
After masking/blocking is removed for 2 minutes, 862EX-AM will send tamper restore signal to the Control Panel.
DIP Switch Position Table
The function of each DIP Switch is listed in the table below. The DIP Switch is either ON or OFF. Top position indicates ON
and bottom position indicates OFF.
2