While arming / disarming the system, the Bellbox uses different methods to distinguish various statuses for the user, as listed in the table.
*
The Siren Audio indication will be affected by the Confirmation ON / OFF setting. When setting Confirmation to OFF, the confirmation sound
will not be available. Refer to Control Panel Sound/Siren setting for Confirmation function.
Getting Started
Learning
Step 1: Release the bottom screw of the Bellbox using a Philips screwdriver and remove the top cover.
Step 2: Put the Control Panel into learning mode (refer to Control Panel’s user manual for details).
Step 3: Slide the battery switch to ON position to power on the Bellbox. All LEDs will flash once and the buzzer will emit 1 beep.
Step 4: Press the Learn button once. The Bellbox will emit a short beep and LED 1 & 3 will turn on briefly. The Bellbox is now in learning mode
and will transmit a learning code to the Control Panel.
Step 5: If the Control Panel did not receive a learning code, press the learn button again (the Bellbox will not sound a beep this time).
Step 6: If the Control Panel receives the learning code, it will list the device information accordingly, follow Control Panel manual instruction to
complete the learning procedure. An acknowledgement will be sent to the Bellbox. When the acknowledgment is received, the Bellbox
will sound a short beep and flash LED 2 once to indicate that learning process is successful. The Bellbox will then leave learning mode.
Step 7: Refer to the Control Panel manual and use Edit Device function to check Bellbox settings. You can edit the operation area, zone number,
and device name for the Bellbox.
<NOTE>
If the learning process fails, please remove the Bellbox from the Control Panel and repeat Steps 4-7 again.
If the Bellbox does not receive the confirm code from the Control Panel within one minute, the Bellbox will leave learning mode. Restart
learning process from Step 4.
Edit Bellbox Operation Area
Follow instruction below to change Bellbox Operation Area in the Control Panel
Step 1: Use the panel Edit Device function to change Bellbox area setting.
Step 2: Press the learn button on the Bellbox to send signal to panel, the Bellbox will emit a beep and flash LED 1 & 3 once.
Step 3: When the Bellbox receives acknowledgement signal from panel, it will emit a beep and flash LED 2 once to indicate the setting has been
updated. The Bellbox will return to normal operation.
Installation
Proceed to installation after complete learning.
Step 1. Disable the Siren Tamper function on the Control Panel (please refer to the Control Panel
instruction manual). The bellbox will sound a beep to indicate the tamper switch is now
disabled.
<NOTE>
The function Siren Tamper will only turn OFF for a duration of one hour. The Control Panel
will automatically turn the function back ON after the duration.
Step 2. Find the location where the Bellbox is to be mounted.
Step 3. Remove the Top cover by releasing the bottom screw using a Philips screwdriver and remove
the top cover.
Step 4. Hold the Bellbox at the position where it will be mounted, supply power to Bellbox
Step 5. Check whether BX has a strong enough signal with the Control Panel by putting the Control
Panel into
Walk Test
mode (please refer to Control Panel manual). Press the
Learn Button
check whether the signal is strong enough (please refer to Control Panel manual for signal
strength).
Step 6. If you are satisfied with the signal strength, Identify the 3 mounting holes, mount and fix the Bellbox on the wall using the large screws
and wall plugs provided. Secure the screws using a Philips screwdriver. Make sure the Tamper Switch is fully depressed against the wall
<NOTE>
The tamper switch protrudes through the back of the unit. When the siren is
pulled off from the wall, the alarm will be activated. Ensure it is fully depressed
when the siren is mounted. If there is a gap, pack with suitable spacing material.
Siren Audio
Strobe light indication
Arm/Home
1 beep*
3 LED groups flash once
Disarm
2 beeps*
Sequentially flashes for 1 cycle
Arm (Low Battery)
3 beeps
3 LED groups flash for three times
Disarm (Low Battery)
3 beeps
Sequentially flashes for 3 cycles
Arm (Tamper)
5 beeps
3 LED groups flash for 5 times
Disarm (Tamper)
5 beeps
Sequentially flashes for 5 cycles
Entry/Exit Sound