28
to Listen-in, but call recipient can press DTMF keys to open two-way communication or change
modes.
-
If Ringer is Enabled for Incoming Calls, CTC-1052-QT-DT35AW will emit ring tone for incoming
calls even in silent mode.
-
Silent mode will not mute the long beep emitted during walk test.
-
When Silent Mode is Off, all warning beeps, guard time tone, key tone and rings will function
noramlly.
37# AC Fault Report:
-
When set to ON, CTC-1052-QT-DT35AW will send a Fault Report after a continuous one hour
of AC Fault condition is detected.
-
When set to OFF, CTC-1052-QT-DT35AW will not send an AC fault report.
38# Follow-On & Call-Back Function:
-
When selected as
“Follow-On”
, after a successful reporting to the Monitoring Center, CTC-
1052-QT-DT35AW will automatically enter the specific Follow-On mode as specified by
Command (
45
). (Reserved)
-
When selected as
“Call-Back”
, after a successful reporting to the Monitoring Center, CTC-
1052-QT-DT35AW will automatically hang up the line and start a 5-minute waiting period to
auto answer any incoming phone calls from the Monitoring Center.
-
When selected as
“Follow-On & Call-Back”
, after a successful reporting to the Monitoring
Center, CTC-1052-QT-DT35AW will automatically enter specific Follow-On mode. Once
Follow-On Mode is terminated, CTC-1052-QT-DT35AW will automatically start a 5-minute
waiting period to auto answer any incoming phone calls from the Monitoring Center.
40# Set Access Code:
-
The Access Code is used to enter Programming Menu, and the Call-Back Function. It consists
of 4 digits and has been set to (1111) as factory default.
-
To set a new Access code, enter the desired (4-digit number) in this field.
41# Auto Answer for Remote Programming:
-
CTC-1052-QT-DT35AW can be programmed to auto answer incoming phone calls after a pre-
set number of rings have been reached. The number of rings ranges from (
01
) to (
09
) rings.
-
When set as “
None
”, CTC-1052-QT-DT35AW will not auto-answer the call by ring count. If
Remote programming is required, you will need to call CTC-1052-QT-DT35AW twice.
42# Guard Time Delay:
-
Guard Time Delay is a time period programmed to delay alarm reporting. If a false alarm is
raised, it can be cancelled within this Guard Time Delay time.
-
Guard Time Delay is designed for any compatible sensor, except Fall Sensor (fall detection).
The delay time can range from (00) (instant reporting) to (99) seconds.
-
Emergency alarms activated by Smoke Detectors (SD), Carbon Monoxide Detectors (CO),
Carbon Dioxide Detector (CO2), Temperature Sensor (TS), and Water Sensors (WS) do not
have Guard Time Delay and will be reported immediately.
-
The Guard Time Delay time from pressing the Active Button on a Fall sensor is determined by
Command #42 Guard Time Delay, instead of Command #66 Guard Time Delay Time for Fall
Sensor.
-
The Guard Time Delay time from Fall detection is determined by Command #66 Guard Time
Delay Time for Fall Sensor, instead of Command #42 Guard Time Delay.