5.3 Walk Test (Range Test)
Walk Test, or Range test, is a test to check
whether learned-in devices are within signal
range.
You can conduct Walk Test in CTC-1052-QT-
DT35AW under 3 different modes as listed
below.
5.3.1. In Learning Mode
Learning Mode is applicable to all devices.
Step 1.
Press and hold the Learn Button of the
CTC-1052-QT-DT35AW.
When
pressed, the CTC-1052-QT-DT35AW
will emit one beep sound initially, and
then emit a double beep on the 6
th
second followed by a voice prompt
“Release the button, Ready to learn
sensor.” Release the Learn Button right
after the double beep and the voice
prompt.
Step 2.
CTC-1052-QT-DT35AW is now in
learning mode and the Purple backlight
will turn on.
Step 3.
Move the device to your desirable
location in the house, and press the
Learn/Test button
of the device to
observe the range of its operation.
Step 4.
If CTC-1052-QT-DT35AW responds
with
one
long beep
, then the particular
device is within the operation range.
Step 5.
To exit Learning Mode, press the Learn
Button once. Otherwise, CTC-1052-
QT-DT35AW will exit Learning mode
automatically after 5 minutes of
inactivity.
5.3.2. In Walk Test Mode
Walk Test Mode is only applicable to Smoke
Detector (SD), Carbon Monoxide Detector (CO),
Motion Sensor (IR), and Water Sensor (WS).
Step 1.
Upon exiting Learning Mode, CTC-
1052-QT-DT35AW will automatically
enter Walk Test Mode for the devices
mentioned above (SD, CO, IR, WS).
Step 2.
Move the device to your desirable
location in the house, and press the
TEST button
of the device
to observe
the range of its operation.
Step 3.
If CTC-1052-QT-DT35AW responds
with
one
long beep
, then the particular
device is within the operation range.
Step 4.
CTC-1052-QT-DT35AW
will
automatically exit Walk Test Mode after
3 minutes.
5.3.3. In Idle Mode
Idle Mode is only applicable to Smoke Detector
(SD), Carbon Monoxide Detector (CO), Motion
Sensor (IR), and Water Sensor (WS).
Step 1.
Press the
Test button
of the devices
mentioned above (SD, CO, IR, WS),
and a signal will be sent to CTC-1052-
QT-DT35AW indicating it is ready to
conduct Walk Test.
Step 2.
Within 30 seconds,
Move the device to
your desirable location in the house,
and press its
TEST button
again to
observe the range for its operation.
Step 3.
If CTC-1052-QT-DT35AW responds
with
one
long beep
, then the particular
device is within the operation range.
Step 4.
Please wait for at least 30 seconds
before conducting Walk Test for
another device under Idle Mode.
5.4 Global Test
Global Test is used to test if the complete
system is working properly.
To do the Global Test:
Step 1.
Press the
RESET
button once.
Step 2. Within 5 seconds
, press Pendant
button.
Step 3.
CTC-1052-QT-DT35AW will emit a
short beep, voice prompt “Global
Test”, and report to Monitoring
Center.
5.5 Manual Test Report
Test Report is used to test if panel can make
a successful report to the CMS.
To make a Test report:
Step 1.
Press the
TEST
button once.
Step 2.
1052-QT-DT35AW will play voice
prompt “Test Call being placed”,
and dial the test call number to
CMS.