Exit (No Response)
If checked, the panel will ignore trigger signal from this sensor during Exit Time
countdown. If deselected, the panel will activated burglar alarm and report
immediately when the sensor triggered during Exit Delay Timer.
24HR
A sensor set to 24HR attribute will ignore Disarm, Full Arm, Home are and Exit
response setting. The panel will activate selected alarm when this sensor is
triggered regardless of system mode under any time.
<NOTE>
Some devices have their own unique functions and will have its own attribute setting
which is not listed in this section. Please refer to the device manual for its setting detail.
5.1.4. Delete Devices
Step 1.
To delete a sensor, click “
Delete
” under “
Device List
”
Step 2.
A message “
Delete success
” is displayed and the sensor you choose is deleted
successfully.
5.1.5. Identify ZigBee Device
The Identify function is available for ZigBee device only, it can be used to locate ZigBee devices
after learning.
For battery powered ZigBee devices, the identify fuction should be used within 1 minute after
pressing device button, or 3 minute after learning in the device. Otherwise due to ZigBee
network mechanisms, the device may not be able to receive signal successfullly from panel.
AC powered ZigBee devices do not have such limits and you can use Identify function anytime.
Step 1.
Click “Identify” under the Device List after the device column entry.
Step 2.
If the ZigBee device receives signal successfully, the webpage will display a success
message and the ZigBee device LED indicator will flash 10 times to confirm.
<NOTE>
If a timeout message is displayed on webpage, it means the device did not receive
signal from Control Panel, please check ZigBee device range from panel and make
sure to follow instruction above about Identifying battery powered ZigBee devices.