5.4. Walk Test
This is to test the sensor operation range for installation purpose.
Step 1.
Click “
Start
” to enter Walk Test mode.
Step 2.
Press the test button on the sensor(s) or any button on the Remote Controller or
triggering the sensor.
Step 3.
When the Control Panel receives a signal, it will show as below and a 2-tone beep will
be heard to indicate that it is safe to install the particular sensor in the location.
Time
: time informaiton
Area
: operation area
Zone
: device zone
Type
:
device type
Name
:
device name
Rssi
: the RF signal strength between Control Panel and sensor. The Rssi value here
must be higher than the Rssi value of Panel’s background noise (please refer to
6.1
Panel Condition section for details
). If not, you may still learn in the sensor; however,
please relocate the sensor and use Walk test to find a more suitable location.
DeviceID
: device’s unique identification code.
Step 4.
Once all sensors are tested, click on “
Stop
” to exit Walk Test mode. The system will
automatically exit Walk Test mode if left idle for 5 minutes.
25