19
1 failed, Mobile Lite will carry on reporting to Index 4.
If all reporting in a group failed, Mobile Lite will retry reporting.
Mobile Lite will try reporting within the same group for
up to three times
,
(or until one of the reports is successful). If three times of trying within the
same group failed, Mobile Lite will regard reporting to this Group
unsuccessful.
From the example above, suppose all report failed, the report sequence
would be:
1 > 4 > 1 > 4 > 1 > 4
Reporting Cycle
If multiple groups are assigned to the same event type (emergency or
status), Mobile Lite will report according the group numeric order from the
first programmed Group to the last programmed group. This report
sequence is one reporting cycle.
Reporting cycle is regarded as successful if any Group is successful, but
Mobile Lite will terminate reporting only after completing the reporting
cycle (going from the first programmed group to the last programmed
group).
Reporting behavior depends on the event type:
Emergency
Events
:
-
When reporting to the first group is successful, Reporting is
regarded as successful. Mobile Lite will still report to the next
group until all groups have been tried to complete the reporting
cycle.
For example, Groups 1 and 3 are assigned to Emergency
Events:
If Group 1 is successful, Mobile Lite will still report to Group 3.
If reporting to Group 3 is successful, Mobile Lite will terminate
reporting.
If reporting to Group 3 is unsuccessful (going through all the
Report Indexes within the group for 3 times), Mobile Lite will
also terminate reporting.
-
When reporting to the first group failed (going through all the
Report Indexes within the group for 3 times), Mobile Lite will
start reporting to the next group. When reporting to the second
group succeeds, reporting is regarded as successful. If no
other group is programmed, Mobile Lite will stop reporting. If
there are more groups programmed, Mobile Lite will continue
reporting until all groups have been tried to complete the
reporting cycle.