27
the alarm will be activated
4.10. Keypad Lockdown
The Control Panel features Keypad Lockdown
function to prevent continuous User PIN Code
retries: If the wrong User PIN Codes are
entered for 5 times within 10 minutes, the
keypad will be locked down for 15 minutes. All
key presses from Control Panel keypad or
Remote Keypads are prohibited during the 15
minute period.
4.11. Tamper Protection
The Control Panel is tamper protected from
unauthorized removal from mounted surface.
When the tamper is triggered:
If the system is in Arm mode:
The Control Panel will always activate a
Tamper Alarm upon tamper switch trigger
and report the alarm event.
If the system is in Home/Disarm mode:
When Tamper Alarm is set to
Away Only
,
no alarm will be activated when a tamper
switch is triggered under Home/Disarm
mode. A report for tamper trigger will still be
reported.
When Tamper Alarm is set to
Always
, the
Tamper Alarm will also be activated when a
tamper
switch
is
triggered
under
Home/Disarm mode.
For Tamper Alarm setting please refer to
2.6. General Setting
.
Avoiding accidental Tamper alarm when
changing
device
battery/mounting
location:
Step 1:
Use the Bypass function to temporarily
deactivate the device to avoid tamper
trigger.
Step 2:
For Indoor Siren or Outdoor Bell Box,
you also need to disabled the Siren
Tamper temporarily.
Step 3:
After finish changing battery or
mounting location, remove the Bypass
setting and enable Siren Tamper again
4.12. Stop the Alarm and
Alarm Display
During an alarm, the Control Panel wil sound
the siren, and report to programmed telephone
number. The screen will display
―ALARM!
ALARM!
‖ to notify the user.
Stopping the Alarm
Step 1:
To Stop the alarm, disarm the Control
Panel, please refer to
4.5. Disarm
for
detail.
Step 2:
The alarm will be stopped, the device
that triggered the alarm will be
displayed on screen. Use the Down
button to scroll down the alarm event,
the screen will display whether the
system
reported
successfully
to
programmed destination or not.
Step 3:
When you finished viewing the alarm
event, the Control Panel will enter
Disarm mode.
<IMPORTANT NOTE>
The Remote Controller cannot be
used to stop the panic alarm triggered
by itself.
Alarm Memory
You can use the Alarm Memory option to
check previous alarm history.
Step 1:
Under the User Manual, select
Alarm
Memory
and press
OK
to confirm. If
alarm memory exists in the Control
Panel, the screen will display:
S T A R T
Step 2.
Press
Down
key to scroll through the
alarm events. When all alarm event
are displayed, the screen will show:
E N D
Step 3.
You can press
Up
key to scroll back
through the fault events or press
OK
key to exit Alarm Memory.
4.13. Voice Report and Call
Acknowledgement
The Control Panel will dial a number during
voice reporting. When the call recipient picks
up the phone, the Control Panel will delay 5
seconds before starting to play the message.
The Voice message is composed of 2 parts:
1. Address Message: The address message
you recorded. If no Address Message is
recorded, the panel will play message
―Alarm System‖.