56
6.4. Event Code
100 – Medical
101 – Personal emergency
When
the Wrist
Transmitter
/
Emergency
Pendant
(WTR)
is
pressed.
102 – Inactive
110 – Fire
111 – Smoke
When the Smoke Detector (SD) is
triggered.
114 – Heat
When the Heat Detector (HD) is
triggered.
120 – Panic
When the Panic Button of the Remote
Controller (RC) is pressed.
121 – Duress
When the Duress Code is entered to
disarm or arm the system.
122 – Silent Panic
When the panic button on a Remote
Controller (RC) set to silent panic is
pressed.
130 – Burglar
When an Instant Burglar Alarm is
triggered
When an Instant Silent Burglar Alarm
is triggered
131 – Burglar Perimeter
When Entry Time is triggered under
Away Arm mode and the timer expires
without disarming the system.
When a Delay Burglar Alarm device is
triggered during Away Entry Time and
the timer expires without disarming the
system.
132 – Burglar Interior
When Entry Time is triggered under
Home Arm mode and the timer expires
without disarming the system.
When a Delay Burglar Alarm device is
triggered during Home Entry Time and
the timer expires without disarming the
system.
133 – 24 Hours
When a device set as
24 Hour
is
triggered.
136 – Burglar Outdoor
When a Burglar Outdoor Alarm is
triggered.
137 – Panel Tamper
When the Control Panel tamper switch
is triggered.
139 – Verification / Alarm Confirmation
147 – Sensor Supervisor Failure
When the Control Panel fails to
receive the signal transmitted from any
one of the devices individually for a
preset period.
151 – Gas
154 – Water leakage
When a Water Sensor or Door Contact
set as
Wate
r is triggered.
158 – High Temperature
When the temperature exceeds High
Temperature setting.
159 – Low Temperature
When the temperature drops below
Low Temperature setting.
162 – CO detector
301 – AC Failure
When the AC power fails for more than
10 sec.
302 – Low Battery
When the battery voltage of the Panel
and any one of the devices is low.
311 – Panel Battery Missing/Dead
When the Control Panel Battery is
missing or disconnected.
344 – Interference
374 – Arm with Fault
When fault exists in system, and the
system is armed by confirming the arm
action. (Arm Fault Type set to
Confirm.)
380 – Device AC Failure
When an AC power accessory device