background image

10 

Spare parts list

No.

Designation

1

Control

2

Air outlet grid

3

Housing part, closed

4

Adapter ring

5

Housing part, with air intakes

6

Power supply cable

7

Filter unit

8

Filter unit sealing cover

11 

Accessories

Thanks to the 3-1 True Hepa filter cartridge,

replacing individual filters is not necessary.

The 3-1 True Hepa filter cartridge can be obtained

from our Climia Online Shop with the article

number 1123329.

Fig. 18: Replacement filter QR code

12 

Technical data

Series

 

CLR 250

Operating mode

 

Compact air purifier

CADR

m

3

/h

250

Effective area

m

2

<30

Usage limits

°C/r.H.%

-10 to +40/35-85

Sound pressure level min./max.

dB(A)

29-52

Power supply

V/Hz

230/1~/50

Indoor unit dimensions (d/h)

mm

233/400

Weight

kg

3.65

 

 

 

CLR 250 air purifier

 

 

16

Summary of Contents for CLR 250

Page 1: ...A Air purifier CLR 250 Operating manual Edition1 0 english español français italiano Instrucciones de operación Manuel d utilisation Manuale d uso nederlands Gebruiks handleiding deutsch Bedienungs anleitung ...

Page 2: ...erating instructions carefully before commis sioning using this device These instructions are an integral part of the system and must always be kept near or on the device Subject to modifications No liability accepted for errors or mis prints ...

Page 3: ...ranty 5 1 5 Intended use 5 1 6 Transport and packaging 5 2 Unit description 6 3 Operation 8 4 Before commissioning 10 5 Commissioning 11 6 Filter change 12 7 Filter cleaning 13 8 Care and maintenance 14 9 View of the unit 15 10 Spare parts list 16 11 Accessories 16 12 Technical data 16 13 Declaration of conformity 17 14 CADR test report 18 15 Index 19 CLIMIA 3 ...

Page 4: ...lammable explosive combustible abrasive and dirty areas or atmospheres n Contact with equipment parts or components can lead to burns or injury n Installation repair and maintenance work may only be carried out by authorised specialists Visual inspections and cleaning can be per formed by the operator as long as the unit is disconnected from the power n Appropriate hazard prevention measures must ...

Page 5: ...nty to Climia Intakt GmbH at the time when the units are purchased and commissioned The warranty conditions are detailed in the Gen eral business and delivery conditions Further more only the parties to a contract can conclude special agreements beyond these conditions In this case contact your contractual partner in the first instance 1 5 Intended use The units have been designed as air purifiers...

Page 6: ...es such as dust fluff hair and animal fur Protects the filter by maximising the filter life B True HEPA filter Removes at least 99 97 of airborne parti cles with a diameter of 0 3 microns Filters small particles such as mould spores minute dust particles smoke particles and allergens such as pollen dandruff or mites C Highly effective activated carbon filter Smoke odours and vapours are physically...

Page 7: ... purify the air effectively keep windows and doors closed when the air purifier is in opera tion Air humidity Humidity can damage the filter This air purifier must only be used in an environment with a humidity below 85 RH If you use the air purifier in an exceedingly high humidity environment the surface of the filter will become mouldy Mould can form due to water or moisture Air purifiers cannot...

Page 8: ...ctive not active indicator 8 Recommended filter change display 9 Key for activating deactivating the unit lighting 10 On off key On Off key This key switches the air purifier on and off Fan speed setting key The fan speed can be adjusted by pressing this key There are a total of 3 fan speed available low medium high The currently set fan speed is indicated by the lighting up of the Roman numerals ...

Page 9: ... filter change If the Filter change symbol lights up the filter must be checked for contamination and cleaned if necessary We urgently recommend replacing it if it is heavily soiled The durability of the filters is heavily dependent on the air quality in the room and the period of use A humid environment lowers the service life of the filter Sleep function key Pressing this key activates deactivat...

Page 10: ... is on the under side of the unit Turn the sealing cover anti clockwise so that the marking of the lock symbol points to open Fig 5 Open sealing cover 2 The sealing cover can now be removed and the filter unit can be taken out Fig 6 Removing the filter unit 3 Remove the packaging material of the filter unit 4 Put the filter unit back in and put the sealing cover back on Ensure that the marking is ...

Page 11: ... Auto matic operating mode Press the Automatic key to do this The fan speed now adjusts automatically to the corresponding air quality The following applies LED colour Blue Green Orange Red Air quality Very good Good Risky Hazardous to health Fan speed Sleep I low II medium III high Setting up the SmartLife App The CLR 250 can also be conveniently controlled remotely via an app To do this use the ...

Page 12: ...ing the surface The sealing cover of the filter unit is on the under side of the unit Turn the sealing cover anti clockwise so that the marking of the lock symbol points to open Fig 10 Removing the sealing cover 3 Remove the sealing cap and carefully remove the filter unit Proceed carefully so as not to distribute the dirt particles picked up by the filter in the room We recommend dis posing of th...

Page 13: ...Press and hold the key for 3 seconds The symbol lights up Press and hold the key again for 3 seconds until the lighting goes out The filter indicator is now reset 7 Filter cleaning In order to increase the efficiency and service life of the filter unit we recommend cleaning the pre filter at intervals of 2 weeks Proceed as follows 1 Remove the filter unit see chapter Filter change 2 Use a H13 or H...

Page 14: ...elec trical power n Cleaning the housing Only clean the unit using a damp cloth Do not use a water jet n Do not use any caustic abrasive or solvent based cleaning products n Only use suitable cleaning agents even in the event of severe soiling n Ensure that no moisture gets into the unit Clean the exhaust air and outlet openings reg ularly and thoroughly This is where dirt most often collects firs...

Page 15: ...9 View of the unit Fig 17 View of the unit CLR 250 CLIMIA 15 ...

Page 16: ...g individual filters is not necessary The 3 1 True Hepa filter cartridge can be obtained from our Climia Online Shop with the article number 1123329 Fig 18 Replacement filter QR code 12 Technical data Series CLR 250 Operating mode Compact air purifier CADR m3 h 250 Effective area m2 30 Usage limits C r H 10 to 40 35 85 Sound pressure level min max dB A 29 52 Power supply V Hz 230 1 50 Indoor unit ...

Page 17: ...aße 13 D 32758 Detmold Equipment machinery variant Air purifier Series Class CLIMIA CLR 250 Series Class Number 2102 2103 Applicable provisions EU Directives The aforementioned products comply with the following EU directives 2014 35 EU Low voltage directives 2014 30 EU Electromagnetic compatibility 2014 53 EU RED Applicable standards EN 60335 2 65 2003 A1 2008 A11 2012 EN 60335 1 2012 A11 2014 A1...

Page 18: ...ifier to switch high speed negative anion setting to work 0 14134 0 14255 0 14134 Total Decay Constant Kt 6 Turn off the air purifier test natural decay constant in the same test conditions to compare 0 00141 0 00138 0 00141 Natural Decay Constant Kn 4 Test result respective in the range of 23 27 40 60 RH stop to pass the smoke when particle concentration reach to rated value the fan keep stiring in ...

Page 19: ...ssioning 11 D Declaration of conformity 17 Disposal of equipment 5 E Environmental protection 5 Exploded view 15 F Filter change 12 Filter cleaning 13 O Operation Control panel 8 S Safety General 4 Identification of notes 4 SmartLife App 11 Spare parts list 16 U Unit description 6 W Warranty 5 CLIMIA 19 ...

Page 20: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...

Reviews: