18
CLIMIA
2. Open the air flap on the top of
the unit.
3. Press the power key.
4. Use the set key to select the
desired humidity level in the
installation room.
11.0 Commissioning
Before commissioning the unit or if
local requirements dictate, the air-
inlet grill and air-outlet grill must
be checked for contamination.
Important notes prior to
commissioning
•
All extensions to the electrical
connection must be of a
sufficient cable size and must
only be used fully rolled out or
unrolled
•
Never use the power supply
connection cable as a pull cord
•
After being switched on,
the units operate fully-
automatically until switched off
by the hygrostat or float when
the condensate container is full
•
The condensate container must
be inserted properly
The unit cannot be operated if
the condensate container is not
inserted properly!
•
In order to prevent damage to
the condenser, the units are
equipped with a mechanism
that prevents the compressor
being immediately switched
back on after it is switched off
The units do not switch back
on until a waiting time of
around
3 minutes has elapsed!
•
If the units work in continuous
operation with an external
condensate drainage
connection, refer to the
relevant section
Control panel
MAX.
AUTO
rF
SET
2
1
4
3
5 6
Power key
The POWER key switches the unit on and off.
SET key
Use the SET key to select the desired humidity in the installation
room.
“MAX.” status light
This light indicates that the unit is in continuous operation.
“AUTO.” status light
These lights indicate which humidity level has been set.
“Container full” indicator light
This light indicates that the condensate container is full and must be
emptied
“Defrost mode” indicator light
This light indicates that the automatic defrost system that is
integrated in the unit has switched on the defrost cycle
1
2
3
4
5
6
Commissioning the units
1. Connect the unit's electrical
connection to a properly
installed mains socket.
NOTE
A contaminated grille or filter
must be cleaned or replaced
immediately.
NOTE
In room temperatures below
10°C
and relative humidity
below
40%
, economical use
of the unit can no longer be
guaranteed.
NOTE
Note that the compressor does
not switch on until a waiting
time of 3 minutes has elapsed.
Restart protection!
CAUTION!
The units are only permitted
to be operated with the air
flap open in order to prevent
overheating.
NOTE
The devices can be switched
ON and OFF via an external
time (accessory) if required.