5
CTK 190 mobile air dehumidifier
•
The air-inlet grille must always
be kept free of dirt and loose
objects.
•
The units must not be covered
during operation.
•
The units must be installed
upright and in a stable position.
•
The units must not be
transported while they are
running.
•
All electrical cables on the
outside of the units must be
protected against damage (e.g.
by animals etc.).
•
Before each change of location,
the condensate containers must
be emptied.
•
Appropriate hazard prevention
measures must be taken to
prevent risks to people when
performing installation, repair,
maintenance or cleaning work on
the units.
•
The units and components
should not be exposed to any
mechanical load, extreme levels
of humidity or direct exposure to
sunlight.
Warning of inflammable
substances
Additional safety notes when
handling refrigerant R290
•
The refrigerant R290 fulfils the
requirements of the European
F-Gas regulation.
•
The unit contains 0.122 kg of the
refrigerant R290.
•
The maximum permitted amount
of refrigerant R290 is 0.3 kg.
•
The unit must not be burned,
drilled or pierced.
•
Only use cleaning agents which
have been approved by the
manufacturer for cleaning.
•
The unit must never be operated
in rooms with naked flames (e.g.
gas heaters, open fireplaces, etc.).
•
Refrigerant circuit components
must not be deformed.
•
The contained refrigerant R290 is
colourless and odourless.
•
The unit must not be stored or
operated in rooms which have a
room area of 6 m
2
or less.
•
The accumulation of refrigerant
due to leakages can lead to a
fire and explosions in rooms
which are too small due to the
development of heat or ignition
sources.
•
The units must be stored
carefully. Mechanical damage
must be avoided.
•
Intervention in the refrigeration
circuit may only be done by
certified specialist personnel
taking into account the safety
notes of the manufacturer.
•
Maintenance and repairs
may only be carried out by
authorised personnel who have
the corresponding knowledge in
regards to flammable refrigerant.
WARNING!
Do not use anything other than
the agent recommended by the
manufacturer to speed up a
possible defrosting process or to
clean the unit. The unit may only
be operated and stored in rooms
where there are no devices with
potential ignition sources. Do not
go below the minimum room
area of 5 m
2
. Note that leaking
refrigerant is colourless and
odourless. The unit must not be
burned or pierced!