9
CTK 240 mobile air dehumidifier
8.0 Set-up
For the best economic and safe use
of the units, the following notes
must be followed in full:
•
The units must be set up in an
upright and level position, to
ensure that the condensate can
drain freely
•
To ensure optimum air
circulation, the units should be
set up in the centre of the room,
where possible
•
Ensure that the room air can
be sucked in and discharged
without hindrances
•
Observe a minimum clearance of
50 cm from walls at all times
•
Units must never be set up in the
immediate vicinity of heaters or
other sources of heat
•
Air circulation is improved if the
unit is set up approx. 1 m above
the ground
•
The room being dried or
dehumidified must be closed to
the surrounding atmosphere
•
Avoid having opened windows
and doors etc., and avoid
frequent entry to or exit from the
room as much as possible
•
The units may not be used in
environments containing a
great deal of dust or chlorine,
or in places with atmospheres
containing ammonia
•
The output of the unit is
entirely dependent on the
conditions inside the room, room
temperature, relative humidity
and observance of the set-up
instructions
Min. 0.5 m
distance to wall
Maintain adequate clearance from
heaters or other sources of heat.
Keep windo
ws and do
ors closed!
Fig. 2
Schematic depiction of how to set up the air dehumidifier
9.0 Commissioning
Before commissioning the unit or if
local requirements dictate, the air-
inlet grill and air-outlet grill must be
checked for contamination.
Important notes prior to
commissioning
•
All extensions to the electrical
connection must be of
a sufficient cable size and must
only be used fully rolled out or
unrolled
•
Never use the power supply
connection cable as a pull cord
•
After being switched on,
the units operate fully-
automatically until switched off
by the hygrostat or float when
the condensate container is full
•
The condensate container must
be inserted properly
The unit cannot be operated
if the condensate container
is not inserted properly!
•
In order to prevent damage to
the condenser, the units are
equipped with a mechanism that
prevents the compressor being
immediately switched back on
after it is switched off
The units do not switch back
on until a waiting time of
around 3 minutes has elapsed!
•
If the units work in continuous
operation with an external
condensate drainage
connection, refer to the relevant
section
NOTE
A contaminated grille or filter
must be cleaned or replaced
immediately.
Summary of Contents for CTK 240
Page 1: ...CLIMIA CTK 240 mobile air dehumidifier Operating manual Edition 1 0 English ...
Page 2: ......
Page 21: ...21 CTK 240 mobile air dehumidifier Notes ...
Page 22: ...22 CLIMIA ...
Page 23: ...23 CTK 240 mobile air dehumidifier ...
Page 24: ...Intakt GmbH Climia Klima und Wärmetechnik Niemeierstraße 13 D 32758 Detmold ...