ELECTRICAL CIRCUIT ALARMS
Num
Name
Description
Category
ee1058 Alarm
Inverter
2
Inverter 2 in alarm
Inverter DFS
ee1059 Alarm
missing
comunication
inv2
Inverter 2 Modbus communication error
Inverter DFS
ee1060
Timeout comunication inv2
Inverter 2 communication timeout
Inverter DFS
ee1061 Alarm
Inverter
3
Inverter 3 in alarm
Inverter DFS
ee1062 Alarm
missing
comunication
inv3
Inverter 3 Modbus communication error
Inverter DFS
ee1063
Timeout comunication inv3
Inverter 3 communication timeout
Inverter DFS
ee1070
User side ECV 1.1
User side ECV connection problem
HW Circuit 1
ee1071
Source ECV 1.1
Source side ECV 1 connection problem
HW Circuit 1
ee1072
Source ECV 2.1
Source side ECV 2 connection problem
HW Circuit 1
ee2001
T.Suction Gas
Gas temperature probe 4 fault
HW Circuit 2
ee2002
T.Suction Gas
Gas temperature probe 6 fault
HW Circuit 2
ee2003
P.Suction Heat
Pressure sensor fault, low pressure heating
HW Circuit 2
ee2004
EEV1 blocked
EEV1 blocked
Circuit 2
ee2005 EEV1
blocked
EEV2
blocked
Circuit
2
EE2006
Comp 1 protections
Compressor 1 overload protection
Circuit 2
EE2007
Comp 2 protections
Compressor 2 overload protection
Circuit 2
EE2008
Comp 3 protections
Compressor 3 overload protection
Circuit 2
EE2009
Source Inverter Protection
Source side inverter overload protection
Source 2
ee2010
Pump Change for Source Flow
Switching pump on source side for flow alarm
Source 2
EE2013
Source Pump 1 protection
Source side pump 1 overload protection
Source 2
EE2014
Source Pump 2 protection
Source side pump 2 overload protection
Source 2
EE2015
Source Pump 3 protection
Source side pump 3 overload protection
Source 2
EE2018
Source side protection
Source side ventilation overload protection
Circuit 2
ee2022
T.Discharge C1.1
Compressor 1 discharge temperature probe fault
HW Circuit 2
ee2023
T.Discharge C2.1
Compressor 2 discharge temperature probe fault
HW Circuit 2
ee2024
T.Discharge C3.1
Compressor 3 discharge temperature probe fault
HW Circuit 2
ee2025
T.Source 1
Source 1 temperature probe fault
HW Circuit 2
ee2026
T.Source 2
Source 2 temperature probe fault
HW Circuit 2
ee2027
T.Suction Gas
Suction gas temperature probe fault
HW Circuit 2
ee2028
P.Discharge
High pressure probe fault
HW Circuit 2
ee2029
P.Suction
Low pressure probe fault
HW Circuit 2
ee2030
T.GasRecovery
Recovery exchanger gas temperature probe fault
HW Circuit 2
ee2031 P.GasRecovery
Recovery exchanger gas pressure probe fault
HW Circuit 2
ee2032
T.Ing Recovery
Recovery in temperature probe fault
HW Circuit 2
ee2033 T.Out
Recovery
Recovery out temperature probe fault
HW Circuit 2
ee2037 Alarm
Inverter
1
Inverter 1 in alarm
Inverter APY
ee2038 Alarm
missing
comunication
inv1
Inverter 1 Modbus communication error
Inverter APY
ee2039
Timeout comunication inv1
Inverter 1 communication timeout
Inverter APY
ee2040 Alarm
Inverter
2
Inverter 2 in alarm
Inverter APY
ee2041 Alarm
missing
comunication
inv2
Inverter 2 Modbus communication error
Inverter APY
ee2042
Timeout comunication inv2
Inverter 2 communication timeout
Inverter APY
Summary of Contents for WSAN-XSC3 MF 200.4
Page 20: ...20 WSAN XSC3 MF 90 4 240 4 M02M40N15 01 6 4 Configuration for 2 pipe system ...
Page 45: ...M02M40N15 01 WSAN XSC3 MF 90 4 240 4 45 8 17 Compressor replacement ...
Page 46: ...46 WSAN XSC3 MF 90 4 240 4 M02M40N15 01 8 18 Exchanger replacement ...
Page 47: ...M02M40N15 01 WSAN XSC3 MF 90 4 240 4 47 9 Accessories 9 1 Anti vibration mount support ...