background image

CX-A4

 I

NSTALLATION AND OPERATION MANUAL

  

 

13 Bose

 Equalisation Modules 

 
Each channel on the CX-A4 can have Bose

 

equalisation so 

that its output will be compensated correctly for a wide range 
of Bose

 speakers.  The Bose

 

equalisation module for the 

CX-A4 is a two channel device the CX-A4 requires three 
modules to be installed to allow compensation on every 
channel of the amplifier.   
The Bose

 equalisation module is available in two 

configurations: 

 

Model 8

 – Suitable for Bose

 Model 8 Speakers 

Model 32

 – Suitable for the Bose

 Model 25, 32 and 102 

speakers 

 

Notes:

  

• 

A Bose

 equalisation module cannot be installed to channels with a VCA module 

installed. 

• 

A Bose

 equalisation module consisting of a model 8 channel and a Model 32 channel 

can be manufactured upon request.  Contact our technical department for more details. 

 

14 

Installing Optional Modules 

 
There are three optional modules for the CX-A4; the VCA-2, VCAL-1 & the Bose

 

equalisation module.  Components supplied with the various modules are listed below: 

 

VCA-2:

 Two 40mm M3 hex spacers, one plastic insert & two 3-pin screw terminal plugs. 

VCAL-1:

 Two 40mm M3 hex spacers & two 3-pin screw terminal plugs.   

Bose

 EQ:

 Two 25mm M3 hex spacers. 

 

The CX-A4 connectors to install the VCA modules are to the rear of the amplifier on the 
input PCB clearly marked on the PCB as ‘CON X TO VCA MODULE’ where ‘X’ is 1 or 2 
see below: - 

 

 CON 

1

 = Channel 1&2 

CON 2

 = Channel 3&4

 

 

 When installing modules, follow the instructions below carefully.  Incorrect installation can 
cause damage. 

 

1.  Turn the power off and remove mains cable. 
2.  Remove the top panel.  
3.  Select the CX-A4 connector you wish to install the module to (see notes above) and 

remove the jumpers from it. 

4.  When installing a VCAL-1 or VCA-2, remove the relevant rear panel blanking plate. 
5.  When installing a VCA-2, push the plastic plug into the rear panel ‘clip protect’ hole.  
6.  Two M3 fixing screws can be found adjacent to the CX-A4 connector.  Remove and 

retain these two screws then fix the M3 hex spacers in their place. 

7.  When installing a Bose

 equalisation module, configure the relevant 65Hz filter to ‘IN’ 

and connect a CXL-100 100V line transformer (see section 6) 

8.  Push the 10-way plug onto the CX-A4 connector with the plug aligned so the cable 

approaches it from the rear of the chassis and check that the connector mates with all 
10 pins (important orientation diagrams can be seen on the following page).  

9.  When installing a VCAL-1 or VCA-2,

 

position the 3-pin sockets and switch(es) of the 

VCA through the cut-outs in the rear panel. 

10.  Align the two holes in the module over the top of the two spacers. 
11.  Secure the module with the two M3x6 screws (removed earlier). 
12.  Fit the top panel. 

15-07-02 V9 

Summary of Contents for CX-A4

Page 1: ...Amplifier Installation User Guide V9 0 Cloud Electronics Limited 140 Staniforth Road Sheffield S9 3HF England Tel 44 0 114 244 7051 Fax 44 0 114 242 5462 E mail info cloud co uk Web site http www cloud co uk ...

Page 2: ...s 2 4 Output Details 4 5 100V Line operation 4 6 Configuring the CX A4 for 100V Line operation 5 7 Bridged Mode Operation 5 8 Status Indicators 5 9 VCA Modules 6 10 Peak Limit VCA Modules 6 11 Remote Level Connections 6 12 Bose Equalisation Modules 7 13 Installing Optional Modules 7 14 Field Servicing 8 15 General Specifications 9 16 Technical Specifications 9 15 07 02 V9 ...

Page 3: ... as two individual attenuators or can be linked to operate as a stereo pair with one remote level control 3 Installation The CX A4 is suitable for mounting in a standard 19 equipment rack and occupies two units of rack space Sufficient ventilation must be provided for the unit The amplifier draws cool air through the front panel and exhausts through the right side and care must be taken not to obs...

Page 4: ...LEVEL CONTROL SOURCE SWITCHES INPUT AMPLFIER FROM MONO SOURCE FOUR CHANNELS DRIVEN FROM ONE MONO SOURCE 1 2 3 4 1 2 1 3 2 4 INPUT 1 1 2 3 4 POWER AMPLIFIER LEVEL CONTROL SOURCE SWITCHES INPUT AMPLFIER FROM STEREO SOURCE TWO STEREO PAIRS FROM ONE STEREO SOURCE INPUT 2 1 2 3 4 15 07 02 V9 ...

Page 5: ...rmination will significantly increase cross talk It is also good practice to distance the output wiring from the input wiring Do not make any connections to the unit with the power cable attached 6 100V Line operation Connecting a CXL 100 100W 100V line module across an output of the CX A4 will obtain a 100W 100V line output from that channel The CXL 100 has to be mounted externally of the amplifi...

Page 6: ... two channels should both to be set to the fully clockwise position The output load should then be connected between the two red binding posts of the relevant channels no connection to the black binding posts of the relevant channels You must ensure that the positive wire is connected to the first red binding post and the negative wire is connected to the second binding post Thus for example it is...

Page 7: ... Thats 2150A VCA providing very low distortion and up to 90dB attenuation The VCA module can be wired to provide muting by using an auxiliary relay connected to a fire alarm control panel Note A VCA module cannot be installed to channels that already have a Bose equalisation module installed 11 Peak Limit VCA Modules A two channel peak limit VCA module is available see section 13 for installation ...

Page 8: ...rear of the amplifier on the input PCB clearly marked on the PCB as CON X TO VCA MODULE where X is 1 or 2 see below CON 1 Channel 1 2 CON 2 Channel 3 4 When installing modules follow the instructions below carefully Incorrect installation can cause damage 1 Turn the power off and remove mains cable 2 Remove the top panel 3 Select the CX A4 connector you wish to install the module to see notes abov...

Page 9: ...ut special tools and is available as a tested replacement complete with heat sink Proceed as follows to replace the power module Disconnect all the leads and connectors from the rear of the unit Ensure that the mains supply lead has been disconnected Remove the CX A4 from the equipment rack Remove the top panel The power amplifier modules are arranged as three dual channel units Locate the faulty ...

Page 10: ...ower amplifier Power Input 230V 5 115V 5 available Fuse rating 230V T4A H 115V T8A H This product conforms to the following European EMC Standards BS EN 55103 1 1997 BS EN 55103 2 1997 This product has been tested for use in commercial and light industrial environments If the equipment is used in controlled EMC environments the urban outdoors heavy industrial environments or close to railways tran...

Page 11: ...e and rating as marked on the rear panel The fuse body size is 20mm x 5mm CAUTION Servicing The unit contains no user serviceable parts Refer servicing to qualified service personnel Do not perform servicing unless you are qualified to do so Disconnect the power cable from the unit before removing the top and do not make any internal adjustments with the unit switched on Only reassemble the unit u...