Page 21-45
E
21A
Test Procedure 34 - Z9 (Yellow Wire) and Z10 (Purple Wire) Continuity
1. Turn the key switch to OFF and place the forward and reverse switch in NEUTRAL. Disconnect the bat-
teries and disconnect the Z plug from the controller.
2. Disconnect the 3-wire connector (from potentiometer) at the connection below the charger receptacle.
3. Place the black (-) probe of a multimeter, set to ohms (
Ω
), in the yellow wire female terminal in the 3-
wire plug and place the red (+) probe in the Z9 (yellow wire) connector position in the Z plug (Figure
21-68). The reading should be continuity. If the reading is incorrect, repair or replace the yellow wire.
Make sure that the yellow wire is in the Z9 position on the Z plug, and that the wire terminals are secure
in the 3-wire plug and in the Z plug.
4. Place the black (-) probe of a multimeter, set to ohms (
Ω
), in the purple wire female terminal in the 3-
wire plug and place the red (+) probe in the Z10 (purple wire) connector position in the Z plug (Figure
21-69, Page 21-46). The reading should be continuity. If the reading is incorrect, repair or replace the
purple wire. Make sure that the purple wire is in the Z10 position on the Z plug, and that the wire termi-
nals are secure in the 3-wire plug and in the Z plug.
Test Procedure 35 - 3-Wire Plug on the Potentiometer
1. Turn the key switch to OFF and place the forward and reverse switch in NEUTRAL. Disconnect the bat-
teries. Leave the Z plug connected to the controller.
FIGURE 21-65
FIGURE 21-66
FIGURE 21-67
FIGURE 21-68
OFF
DC V
DATA HOLD
AC V
AC/DC 500V MAX
250V MAX
BATTERY BANK
-
+
+
-
-
-
+
+
2
3
4
6
5
RED PROBE
ON YELLOW
WIRE FEMALE
THREE WIRE
CONNECTION
OFF
DC V
DATA HOLD
AC V
AC/DC 500V MAX
250V MAX
BATTERY BANK
-
+
+
-
-
-
+
+
2
3
4
6
5
RED PROBE
ON PURPLE
WIRE FEMALE
THREE WIRE
CONNECTION
OFF
DC V
DATA HOLD
AC V
AC/DC 500V MAX
250V MAX
BATTERY
BANK
BLACK PROBE
ON WHITE/BLACK
WIRE FEMALE
THREE WIRE
CONNECTION
-
+
+
+
-
-
1
2
OFF
DC V
DATA HOLD
AC V
AC/DC 500V MAX
250V MAX
BLACK PROBE
ON YELLOW
WIRE FEMALE
THREE WIRE
CONNECTION
Z8
Z9
Z10
Z11
Z12
Z13
Z1
Z2
Z3
Z4
Z5
Z6
Z7
Z14
PLACE RED PROBE
INTO THE Z9 POSITION
ON THE Z PLUG
Summary of Contents for 1996 DS Golf Car Gasoline
Page 2: ......
Page 28: ...Page 3 14 3 E G...
Page 38: ...Page 4 10 4 E G...
Page 76: ...Page 6 30 6 E G...
Page 110: ...Page 8 26 8 E G...
Page 136: ...Page 11 6 11 G...
Page 268: ...Page 15 4 15 G...
Page 286: ......
Page 316: ...Page 18 6 18 G...
Page 332: ...Page 19 16 19A E...
Page 350: ...Page 19 34 19A E...
Page 444: ......
Page 451: ...Page 21 59 E 21B FIGURE 21 85 2 4 5 7 8 1 9 6 5 4 3...
Page 452: ...Page 21 60 21A E...
Page 472: ...Page 22 20 22 E...
Page 524: ...Page 23 52 23A E...
Page 543: ......
Page 544: ...Golf Cars Club Car Inc P O Box 204658 Augusta GA 30917 4658...