19
Quick Connect Fittings (Auxiliary Hydraulic Circuit only)
HYDRAULIC ATTACHMENT SYSTEM
QUICK CONNECT FITTINGS (AUXILIARY HYDRAULIC CIRCUIT ONLY)
2252
Figure 19-36
Quick Connect Fitting Removal
QUICK CONNECT REMOVAL
1.
Relieve pressure in hydraulic system.
See Relieving Hydraulic System Pressure on page 19-1.
2.
Set the joystick ON/OFF switch to OFF, remove driver seat and disable vehicle.
3.
Disconnect battery.
See Side-Post Battery: Disconnecting the Battery – Gasoline/Diesel Vehicles on page
1-3.
See Top-Post Battery: Disconnecting the Battery- Gasoline/Diesel Vehicles on page 1-4.
4.
Thoroughly clean the fittings and the area around them.
5.
Mark hoses to ease reassembly and disconnect hoses from quick connect fittings.
See following NOTE.
Cover
hoses and fittings to keep out debris.
NOTE:
Mark hoses for correct installation if factory markings are not found.
6.
Remove the lock nut securing the quick connect fitting to the bracket
QUICK CONNECT INSTALLATION
1.
Reverse the removal procedure to install quick connect fittings. Tighten jam nuts to 30 ft-lb (41 N·m).
2.
Match hose to fitting and connect hoses
. Tighten fittings to 22 ft-lb (30 N·m).
Page 19-24