HYDRAULIC ATTACHMENT SYSTEM
Hydraulic Pump Assembly
19
5.
Lubricate o-ring with new fluid and install reservoir, being careful not to pinch or deform the o-ring. Tighten
clamp to 57 in-lb (6.3 N·m).
6.
Install pump assembly.
See Pump Assembly Installation on page 19-46.
MOTOR
Motor Removal
2309
Figure 19-93
Remove Motor Bolts
2310
Figure 19-94
Motor Bearing
1.
Lift pump assembly out of chassis and remove cradle.
See Pump Assembly Removal on page 19-44.
2.
Note location of and disconnect solenoid wires and remove solenoid.
3.
Match-mark the motor housing to ease reassembly alignment.
4.
Remove two bolts and end cover from motor
5.
Grasp motor housing and armature and pull motor from pump.
See following NOTE.
NOTE:
The motor may require effort to remove because the bearing is also being pulled out of the base
Motor Installation
1.
Align slot in motor armature with pump driveshaft and carefully push the motor and bearing into place
19-95, Page 19-48) (Figure 19-96, Page 19-48)
. Once in place, align mark on motor housing with mark on base.
2.
Align hole in end cover with pin on motor housing and install. Secure with bolts previously removed.
3.
Attach solenoid to motor and connect wires.
See Solenoid Installation on page 19-18.
4.
Assemble pump assembly to cradle and place unit in chassis.
See Pump Assembly Installation on page 19-46.