UNITIZED TRANSAXLE: DASH-MOUNTED
SHIFTER
Unitized Transaxle Removal
20
564
Figure 20-14 Throttle Cable and Retaining Nuts (Top View)
565
Figure 20-15
Engine Ground Wire and Retaining Nut
4.7. Loosen nuts securing shifter cable to shifter cable mounting bracket. Then disconnect the shifter cable rod
end from the shifter arm on the unitized transaxle and remove the cable from the cable mounting bracket
.
4.8. Mark for identification and then disconnect the 6-gauge white wire (F2 post), 6-gauge black ground wire (A2
post), and 16-gauge yellow wire (DF post) from starter/generator
1
2
1. Loosen nuts. 2. Pull spring release back to remove shifter cable
from lever.
DF
F2
1
2
3
1. Yellow Wire 2. White Wire 3. Ground Wire at A2 Terminal
566
Figure 20-16
Shifter Cable (Top View)
836
Figure 20-17
Generator Wires
4.9. Disconnect the engine oil level sensor wire (18-gauge yellow) at the connector just to the rear of the
starter/generator)
.
4.10. Disconnect the engine kill switch wire (18-gauge white/black) from the bullet connector at the lower right
front of the engine
4.11. Cut away the wire ties securing the engine kill wire at the lower right front of the engine (below the exhaust
header), the wire harness at the governor cable bracket, and the wire harness to the plate beneath the
muffler.
2007-2009 Turf 252, Carryall 252 and XRT 900 Maintenance and Service Manual