12
Test Procedures
TROUBLESHOOTING AND ELECTRICAL
SYSTEM: DIESEL VEHICLES
5.
Connect the black (–) probe of the multimeter to the frame (ground).
6.
Connect the red (+) probe of the multimeter to the 14-gauge blue wire (w52) on the two-pin connector (wire
harness side).
7.
The reading should indicate an over limit (no continuity). If the diode conducts current (shows continuity) with
the meter probes connected as described, the diode has failed and must be replaced.
8.
Reverse the multimeter probes and note the reading. The multimeter should indicate approximately 540 mV,
however, a range of 400 to 700 mV is acceptable.
9.
If the readings obtained in the previous steps are incorrect, replace the diode.
TEST PROCEDURE 15 – Diode 3 on wire 123
See General Warnings, Section 1, Page 1-2.
1.
Disconnect battery.
See Disconnecting the Battery – Gasoline/Diesel Vehicles, Section 1, Page 1-3.
2.
Raise the hood.
3.
Disconnect the multi-pin connector from the key switch
See following NOTE.
NOTE:
Failure to disconnect the multi-pin connector from the key switch will result in unreliable results when the
diodes connected to the key switch circuit are tested.
2119
Figure 12-22
Disconnected Multi-Pin Connector at Key
Switch
4.
Disconnect the three-pin connector (w122, w135, w108) between the fuel solenoid and the wire harness
5.
Disconnect the bullet connector, on the gray wire (w140), between the fuel pump and the wire harness
6.
Set the multimeter to the diode test function.
Page 12-26
2013 Carryall 295/XRT 1550 Maintenance and Service Manual
Summary of Contents for Carryall XRT 1550
Page 2: ......
Page 28: ......
Page 40: ......
Page 62: ......
Page 106: ......
Page 120: ......
Page 180: ......
Page 224: ......
Page 272: ......
Page 310: ......
Page 344: ......
Page 362: ......
Page 370: ......
Page 418: ...NOTES...
Page 428: ...NOTES...
Page 430: ...NOTES...
Page 431: ......
Page 432: ......