13.
If one or more conditions shown cannot be done while in storage,
disconnect the negative (-)
battery cable. Make sure that the negative (-) battery cable does not touch the battery terminal.
• The battery charger must stay connected to an electric outlet
• AC electrical power will be available during storage
• Battery acid levels will be kept at a sufficient level while in storage
14.
If all conditions shown can be done while in storage,
do as follows:
• The battery charger must stay connected to an electric outlet
• AC electrical power will be available during storage
• Battery battery acid levels will be kept at a sufficient level while in storage
14.A
Connect the battery charger to the vehicle. Keep battery chargers connected during
storage. The charger will automatically connect when necessary.
14.B
Examine the battery acid level and charger function monthly.
Note:
The charger is operating correctly when the blue light is on and the triangular
light is off.
RETURN TO SERVICE FROM EXTENDED STORAGE
1.
Clean the batteries.
2.
If the batteries were disconnected, connect the batteries.
3.
Fully charge the batteries.
4.
Set the Run/Tow switch to RUN.
5.
Set the Forward / Neutral / Reverse control (FNR) to N.
6.
Adjust the pressure in each tire to the recommended tire pressure.
7.
Have a trained technician lubricate the vehicle.
8.
Do a daily pre-operation safety checklist.
9.
Do a vehicle performance inspection.