ENGLISH
36
TECHNICAL MANUAL
10.2 Failures and functional problems
1.
Start the machine as described in the user
manual
2.
Check the mains switch
3.
Check connection to the electricity mains
1.
Machine switch on
0
2.
Mains switch on
OFF
3.
Mains connection does not conform
cause
remedy
problem
THE MACHINE DOES NOT
TURN ON
NO STEAM IS COMING
FROM THE STEAM SPOUT
1.
Change the top gaskets
1.
Top gaskets deteriorated
WATER IS LEAKING FROM
THE TOP OF THE
DISPENSING UNIT
WATER IS LEAKING FROM
THE BOTTOM OF THE
DISPENSING UNIT
1.
Faulty heating element
2.
Pressure switch contacts rusted
3.
Heating element protection triggered
3.
The spray is clogged
1.
Change the heating element
2.
Clean the contacts of the pressure switch
or change it
3.
Rearm the heating element protection
4.
Clean the sprays spout
WATER IS LEAKING FROM
THE MACHINE
1.
The drain is clogged
2.
Drainpipe broken or has come away
3.
Water leaking from fittings or from the
pipes of the internal hydraulic circuit
1.
Check the drainage system
2.
Check the drainpipe
3.
Restore watertightness by changing the
pipe, gasket or fitting
A MIXTURE OF STEAM AND
WATER IS COMING FROM
THE STEAM SPOUT
1.
Boiler water level is too high because
the boiler level probe is wrongly
positioned or there is limescale on it
1.
Check the position of the level probe and
change it if necessary
WATER IS LEAKING FROM
THE INTERNAL PUMP
1.
Bottom gaskets deteriorated
2.
Fitting and/or pipe deteriorated
1.
Change the bottom gaskets
2.
Change the fitting and/or pipe
1.
No mechanical seal of the shaft or O-
ring
2.
Fittings have loosened
3.
The hexagon nut of the limiter valve or
of the filter has come loose
4.
The gasket or the O-ring of the limiting
valve or of the filter has deteriorated
1.
Check the pump
2.
Tighten the fittings
3.
Tighten the fittings
4.
Change the gasket taking care not to alter
limiting valve calibration
THE PUMP IS MAKING A
LOT OF NOISE
1.
Pump and motor not aligned
2.
The gasket or the O-ring of the limiter
valve or of the filter has deteriorated
3.
The joint or the coupling screw or the
V clamp has come loose
4.
Obstruction, even partial, of the pump
inlet
5.
The hexagon nut of either the limiting
valve or of the filter has come loose
1.
Realign pump and motor
2.
Change the pump
3.
Align and tighten
4.
Clean or change the inlet filter
5.
Tighten the hexagon nut
All manuals and user guides at all-guides.com