If the motor was started using the cold start
aid.
Push the cold start lever (3) back to the starting
position.
Switching the motor off
Figure 6 – Page 4
– Set the ignition switch (10) to OFF.
– Set the fuel tap (4) to OFF.
Connecting the consumers
Alternating current connections
Figure 1 – Page 3
The alternating current connectors (14) of the device
are intended to be used to operate consumers that
use 230 V and require alternating current (50 Hz)
(
– The connec-
tion cable of
the consumer
should be
wound 2 or 3
times around
the bar of the
device.
When the motor is running or at operating tem-
perature
– Insert the plug of the consumer into one of the
AC connectors (14) of the device.
Safety devices
Overload protection
Figure 7 – Page 4
After triggering the circuit-breaker:
– Eliminate cause of overloading.
– Activate the circuit-breaker switch (13).
Switch position to:
ON = Circuit-breaker active
OFF = Circuit-breaker triggered
Cleaning and maintenance
CAUTION! Device damage!
Before
switching the motor off, switch off any
connected consumers and disconnect
from the device (unplug).
WARNING! Risk of injury!
Before con-
necting consumers check to see whether
all electrical equipment, including cable
and plug connections are in good working
order.
WARNING! Risk of injury!
Make sure that
you only connect consumers that are
switched off.
CAUTION! Device damage!
The overall
load of the connected consumers must lie
within the nominal load, otherwise dam-
age to the device may occur (
).
Note:
Make sure that the plug of the con-
sumer fits into the corresponding socket
of the device. If a consumer does not run
properly, pull out the consumer plug from
the power supply of the device immedi-
ately.
Note:
The extension cable must have the follow-
ing minimum cable cross-sections:
• up to 60 m length, minimum of
1.5 mm²
• up to 100 m length, minimum of
2.5 mm²
Rubber-coated cables (IEC 60245-4,
DIN VDE 0282-4) of type H05 RN-F must
be used.
Note:
If the permissible load limits are
exceeded, the overload protection of the
device is automatically triggered. The cir-
cuit-breaker switch is ejected and the
electrical supply of the consumer is inter-
rupted.
WARNING! Risk of injury!
Prior to conducting maintenance or clean-
ing:
– Switch the motor off.
– Allow the device to cool down.
– Pull out the spark plug connector.
106554_Generator_Benzin.book Seite 47 Montag, 21. November 2016 4:30 16
Summary of Contents for 106554
Page 5: ...5 10 9 20 106554_Generator_Benzin book Seite 5 Montag 21 November 2016 4 30 16...
Page 123: ...RU 123 18 LWA 134 XX 106554_Generator_Benzin book Seite 123 Montag 21 November 2016 4 30 16...
Page 124: ...124 RU 134 134 106554_Generator_Benzin book Seite 124 Montag 21 November 2016 4 30 16...