background image

5

C. OPERATION

1. OPERATION FOR ALL SKIMMERS

•  Water is pulled through the skimmer by the suction of the pump. Water flow carries floating debris into the skimmer 

where it is collected in the skimmer basket. 

•  The floating weir creates a better water flow and increases efficiency. 

•  The water level of the pool should be kept at least 2” above the bottom of the mouth of the skimmer to ensure proper 

operation. 

•  To adjust the skimmer flow rotate the diverter plate on the float valve or in the skimmer until the desired flow is achieved.

•  If multiple skimmers are installed, rotate the diverter plate in each skimmer over the pump port to restrict and balance 

the flow from each skimmer. 

•  To vacuum the pool, remove the float valve and close the diverter plate over the main drain. Install the skimmer vacuum 

in the skimmer and connect to vacuum hose.

•  Empty the skimmer basket as needed to maintain flow through the skimmer.

•  To enhance skimming on low flow pump settings, set drain & skimmer three-way valve to divert suction to skimmer (if a 

valve is present).

2. OPERATION WITH DIVERTER PLATE

•  For full flow, rotate diverter plate completely open. 

•  To adjust flow, rotate over the pump port until desired flow is achieved. 

•  To vacuum, either remove cover and basket OR insert the skimmer vacuum into skimmer on top of the basket. Screw the 

hose adapter into the pump port. Fill hose with water and insert over the hose adapter.

3. OPERATION WITH FLOAT VALVE (OPTIONAL)

•  If the water level drops below the mouth of the skimmer or if the basket is clogged and no water can flow through it, the 

float valve will automatically close over the flow ports. 

•  This diverts all water flow to the pump from the main drain line and prevents possible air lock.

•  When the pump is shut off or water level returns to normal, the float valve will float back to the top of the cavity, allowing 

normal operation to resume. 

A

A

SECTION A-A

SCALE 1 : 8

BOTTOM VIEW

D

C

B

A

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

Custom 

Molded 

Products

Vic Walker

CAD GENERATED DRAWING,
DO  NOT  MANUALLY  UPDATE

SIZE Doc. Number

Part Number

B

SHEET 2 OF 6

REV.

APPROVALS

DRAWN

RESP ENG

UNLESS  OTHERWISE  SPECIFIED

DIMENSIONS  ARE  IN  INCHES

TOLERANCES  ARE:

1/X    1/8

A

 XXXX

Part Name

Vic Walker

XXXX

IR #

.X    .030
.XX    .010

.XXX    .005
.XXXX    .002

Degrees    .5

5-17-21

Scale:

Rev. Date

5-17-21

 XXXX

NONE

-

-

-

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF

CUSTOM MOLDED PRODUCTS.  ANY REPRODUCTION IN PART OR WHOLE WITHOUT

THE WRITTEN PERMISSION OF CUSTOM MOLDED PRODUCTS IS PROHIBITED.

DATE

_

_

_

Float

Valve

Debris

Basket

Weir

A

A

SECTION A-A

SCALE 1 : 8

BOTTOM VIEW

D

C

B

A

A

B

C

D

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

Custom 

Molded 

Products

Vic Walker

CAD GENERATED DRAWING,
DO  NOT  MANUALLY  UPDATE

SIZE Doc. Number

Part Number

B

SHEET 2 OF 6

REV.

APPROVALS

DRAWN

RESP ENG

UNLESS  OTHERWISE  SPECIFIED

DIMENSIONS  ARE  IN  INCHES

TOLERANCES  ARE:

1/X    1/8

A

 XXXX

Part Name

Vic Walker

XXXX

IR #

.X    .030
.XX    .010

.XXX    .005
.XXXX    .002

Degrees    .5

5-17-21

Scale:

Rev. Date

5-17-21

 XXXX

NONE

-

-

-

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF

CUSTOM MOLDED PRODUCTS.  ANY REPRODUCTION IN PART OR WHOLE WITHOUT

THE WRITTEN PERMISSION OF CUSTOM MOLDED PRODUCTS IS PROHIBITED.

DATE

_

_

_

Diverter

Plate

FIGURE 4: SKIMMER OPERATION COMPONENTS

4. SWEEP/BRUSH POOL

•  Divert all suction to the main drain by:

•  OPTION 1: Use valve to divert all water to the suction away form the skimmer.

•  OPTION 2: Hold the weir above normal operating level and allows the float to snap shut. To reset the float valve 

assembly, turn off the pump for 10-15 seconds. The float valve will rise to the top of the skimmer cavity.

•  OPTION 3:  Remove the float valve assembly, close the diverter plate, and replace.

5. VACUUM POOL

•  OPTION 1: Remove cover, basket and float valve assembly. Screw the hose adapter into the pump port, fill the hose with 

water, and insert over adapter. 

•  OPTION 2: Insert the skimmer vacuum into skimmer on top of the basket.

Summary of Contents for 25100 Series

Page 1: ...90500 025 120 RevC C M P COM IN GROUND POOL SKIMMER INSTRUCTIONS INSTALLATION INSTRUCTIONS PRODUCT MANUAL 25100 XXX XXX 25120 XXX XXX 25140 XXX XXX ...

Page 2: ...system at all times If rusting is visible on Water Bond Kit when installed replace kit immediately A SAFETY INSTRUCTIONS PRECAUTIONS CAUTION DANGER DANGER DANGER WARNING WARNING WARNING IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS Use one skimmer per 500 square feet of pool surface area Suction line sizes are based on a water velocity of less than seven feet per second Since buil...

Page 3: ...ly Plug Second Port FIGURE 1 2 PLUMBING The skimmer has two 2 ports for plumbing The rear port should connect to the pool suction The front port may be used as an equalizer line or connect to the pool main drain If the front port is not used it should be plugged Assemble piping and pipe fittings to skimmer All piping must conform to current local and state plumbing and sanitary codes Long pipe run...

Page 4: ...4in Pipe Overflow Port 1in Pipe Overflow Port FIGURE 2 OVERFLOW PORTS 4 WATER BONDING POOL DEFENDER MODELS ONLY FIG 3 Pool Defender models include a bonding wire for integrated water bonding Connect the copper wire in the rear of the skimmer to the pool bonding grid or loop using the provided connector As required in NEC section 680 26 C the bonding device Consists of at least 9 sq in of conductiv...

Page 5: ... pump port Fill hose with water and insert over the hose adapter 3 OPERATION WITH FLOAT VALVE OPTIONAL If the water level drops below the mouth of the skimmer or if the basket is clogged and no water can flow through it the float valve will automatically close over the flow ports This diverts all water flow to the pump from the main drain line and prevents possible air lock When the pump is shut o...

Page 6: ... every few days for accumulated leaves debris etc Empty basket as required Reset float valve if it closed D MAINTENANCE CMP P N DESCRIPTION 1a 25544 000 000 WHITE SKIMMER LID COVER ROUND 1b 25538 500 000 WHITE SKIMMER LID COVER SQUARE 2b 25547 000 000 WHITE SKIMMER COLLAR ROUND 1a 2a 25544 900 000 WHITE SKIMMER COVER COLLAR ROUND 1b 2b 25538 900 000 WHITE SKIMMER COVER COLLAR SQUARE 3 25140 000 90...

Page 7: ...7 E DIMENSIONS 7 3 8 5 1 4 8 1 2 11 5 16 20 1 4 11 3 8 15 16 5 3 4 1 1 2 15 3 8 3 9 16 10 1 4 10 7 16 10 7 16 ...

Page 8: ...__ Purchased From _______________________________________________________ Installation Date _____________________________ Model Number ______________________________ Pool Size in Gallons __________________________ CMP Customer Service Tech Support Toll Free 1 800 733 9060 FAX 770 732 7115 support c m p com Warranty Questions RMA c m p com Support Resource Videos Online c m p com resourcecenter ...

Reviews: