Recirculated - air: Kitchen fumes are
removed and after purification are fed
back into the room through the upper air
outlet openings. The purification takes
place via the grease filters.
4. PARTS SUPPLIED
5. INSTALLATION
Important!
We recommend that two people
carry out the installation. Pay attention to the
procedure described in the assembly
instructions.
Preparation
•
Exhaust operation: The wall breakthrough
(core drill hole, min. 155mm) must be
carried out by a professional prior to
installing the extractor hood.
Pay attention to the length of the exhaust
hose when planning the wall breakthrough.
The exhaust hose must reach the outer
edge of the wall without any kinks.
Important!
If the exhaust hose leads
through an outer wall, the air outlet on the
outside must be equipped with a cover
that has self-opening slits (not supplied).
This can be installed by the company that
performs the wall breakthrough.
If open fireplaces are operated in the same
room, ask your local chimney sweeper
about the local regulations prior to
installation.
If you are renting, then approval must be
obtained from the owner of the property.
•
Attention!
In order for the cooker hood to
reach optimal performance, mount it over
the middle of the cooking area.
•
Plan the power connection prior to
installation so that a disturbing cable will
not be visible afterwards.
•
The following accessories are required to
mount the cooker hood (not included with
the delivery):
→
Exhaust
duct
→
Power
drill
→
Screwdriver
→
Water
level
→
Cable
detector
Electrical connection
•
All fittings must be installed by a qualified
electrician in accordance with current IEE
Wiring Regulations (BS7671) and local
building regulations.
•
Important!
Always switch off the
electricity supply at the mains during
installation and maintenance. We
recommend that the fuse is withdrawn or
circuit breaker switched off a the
distribution board whilst work is in progress.
•
Prior to drilling holes to secure it to the wall,
make sure that no cables or pipes will
become damaged (electric, gas, water,
etc.; test the areas in question with a cable
detector).
•
This unit is double insulated and must not be
earthed. If there are any incoming earth
cables, they must be joined and well
insulated with good quality insulation tape.
This is to ensure earth continuity throughout
your property.
•
Means for disconnection must be
incorporated in the fixed wiring in
accordance with the wiring rules. To
achieve this install appropriate switched
fused connection unit.
Note!
A switched fused connection unit having
a contact separation of at least 3mm in all poles
should be connected in fixed wiring.
•
Connect the incoming positive, neutral and
earth cables to the terminals of the
switched fused connection unit (fig.1 ).
Ensure connections are tight
1