background image

 

Copyright © 2014 CO2 Meter. All Rights Reserved. 

User Manual 

iSense Remote 

Oxygen Safety Alarm   

 

CM

0180

 

 

25%

 

Oxygen

 

CM

0181

 

 

95%

 

Oxygen

 

 

iSense Oxygen Transmitter – Manual

 

CO2Meter.com 

 

Rev. 27 October 2014 

Pg. 2 of 21 

 

Table of Contents 

TABLE

 

OF

 

CONTENTS

 

...................................................................................

 

2

 

WELCOME

 

...................................................................................................

 

3

 

IMPORTANT

 

SAFEGUARDS...........................................................................

 

4

 

DEVICE

 

SPECIFICATIONS

 

..............................................................................

 

5

 

PACKAGE

 

CONTENTS

 

...................................................................................

 

6

 

GASLAB

 

®

 

SOFTWARE

 

..................................................................................

 

6

 

M

INIMUM

 

S

YSTEM

 

R

EQUIREMENTS

 

.......................................................................

 

7

 

Q

UICK

 

S

TART

 

G

UIDE

 

...........................................................................................

 

8

 

D

ESCRIPTION

 

...................................................................................................

 

11

 

STANDARD

 

OPERATION

 

.............................................................................

 

11

 

ENTERING

 

THE

 

SERVICE

 

MENU

 

..................................................................

 

12

 

PERFORMING

 

AN

 

ATMOSPHERIC

 

SPAN

 

CALIBRATION

 

................................

 

12

 

PERFORMING

 

A

 

0%

 

OXYGEN

 

ZERO

 

POINT

 

CALIBRATION

 

............................

 

12

 

TERMINALS

 

CONNECTORS

 

.........................................................................

 

13

 

MODBUS

 

/

 

RS

485

 

.....................................................................................

 

13

 

I

NPUT

 

R

EGISTERS

 

..............................................................................................

 

14

 

H

OLDING

 

R

EGISTERS

 

.........................................................................................

 

14

 

P

OWERING

 

THE

 

U

NIT

 

........................................................................................

 

15

 

LCD

 

D

ISPLAY

 

...................................................................................................

 

16

 

T

HEORY

 

OF

 

O

PERATION

 

.....................................................................................

 

16

 

C

ALIBRATION

 

...................................................................................................

 

16

 

C

ALIBRATING

 

USING

 

MODBUS

 

OR

 

PC

 

C

ONNECTION

 

..............................................

 

17

 

SUPPORT

 

...................................................................................................

 

20

 

WARRANTY

 

...............................................................................................

 

20

 

RETURNS

 

...................................................................................................

 

20

 

LIABILITY

 

...................................................................................................

 

21

 

CONTACT

 

US

 

.............................................................................................

 

22

 

Summary of Contents for iSense CM-0180

Page 1: ...AGE CONTENTS 6 GASLAB SOFTWARE 6 MINIMUM SYSTEM REQUIREMENTS 7 QUICK START GUIDE 8 DESCRIPTION 11 STANDARD OPERATION 11 ENTERING THE SERVICE MENU 12 PERFORMING AN ATMOSPHERIC SPAN CALIBRATION 12 PERFO...

Page 2: ...nd install the software you can use the Check for updates function under the Help menu to search for new updates Please also pay special attention to the important safeguards shown on the pages ahead...

Page 3: ...your package contains the following items before using the unit Contents 1 Meter 1 Certificate of Calibration 1 User Manual 1 Power supply 1 2 Meter USB to RS 485 Cable 1 Screen Breather GasLab Softw...

Page 4: ...cess Memory RAM Hard disk space with at least 20 Megabytes MB free 200 MB recommended for logs and application files Software is compatible with 64 bit operating systems and is fully tested with Windo...

Page 5: ...power supply include you can Turn ON OFF the unit USB Through the USB you can calibrate collect data in real time download data and calibrate the unit using D GasLab software iSense Oxygen Transmitte...

Page 6: ...on During its life cycle calibration may become periodically necessary We recommend performing a span O2 calibration every month for guaranteed operation and ensured accuracy No other calibration is n...

Page 7: ...n Transmitter Manual CO2Meter com Rev 27 October 2014 Pg 14 of 21 Input Registers 1 O2 Value x10 2 Raw ADC Value Holding Registers 1 O2 Span Value 4 byte floating number part 1 2 O2 Span Value 4 byte...

Page 8: ...2 in percentage format for 100 Theory of Operation The zirconia oxygen sensor utilizes solid state electrochemical reactions to produce a voltage proportional to the current oxygen This voltage is the...

Page 9: ...Meter com Rev 27 October 2014 Pg 18 of 21 Calibration of the Oxygen Sensor In the desktop software application O2 can be calibrated individually The O2 sensor can be calibrated to 0 and then to 20 9 D...

Page 10: ...oblem and quickly respond to your inquiry Warranty This unit comes with a 1YEAR warranty period limited manufacturer s warranty starting from the date the unit was shipped to the buyer During this per...

Page 11: ...warranty Finally please ship your device to the address shown under the Contact Us section below CO2Meter com will not under any circumstances be responsible for your shipment expenses and no refund w...