Secondary Operating Screen
Serves as a secondary operating screen and displays additional
information about the status of the Radio Pack. Short press the Menu
button once to toggle between the Home and Secondary screens.
After 60 seconds, the screen will timeout and revert back to the Home
screen.
Note
:
Radio Signal Strength Value displays the actual value of the
radio signal in dBm.
Radio Pack Menu
Radio Pack settings can be accessed and adjusted from the Radio
Pack’s LCD, the Control Unit’s LCD, or via the X-Ware interface on the
touch screen monitor. The following menu tree displays all of the Radio
Pack’s menu options and settings:
Figure 47: RP Secondary Operating Screen Overview
RT Name
Pack Name
Profile Name
Radio Signal
Strength Value
Remaining Battery Time
Pack Info Device Settings User Settings Tech Menu
Page 1
Page 2
Page 3
Model
Profi le
Mode
Serial Number
Firmware Revision
Transceiver
Mic Type
Mic Gain
Auto Detect
Dynamic
Electret
Dynamic Mic Detected:
0 (+6dB) to 10 (+35 dB)
Factory Defaults
Restore Defaults
Clear Memory
Mic Type
Mic Gain
Noise Gate
Contrast
Backlight Brightness
Backlight Time Out
Side Tone
Talk Tones
Volume Min
Volume Max
Edit Backlight Time Out
LCD Timeout
Edit Backlight Brightness
LCD Brightness
Edit Contrast
LCD Contrast
Display Options
Edit Battery Alert
Battery Alert
Short Name
Pack Name
Long Name
Edit Short Name
Edit Long Name
Noise Gate
Very High -48 dB
High -57 dB
Medium -66 dB
Low -75 dB
Disabled
Sidetone
Very High -0dB
High -6 dB
Medium -12 dB
Low -18 dB
Very Low -24 dB
Min Volume
0 (-57 dB) to 19 (+3 dB)
Max Volume
1 (-53 dB) to 20 (+6 dB)
Talk Tones
On
Off
Electret Mic Detected:
0 (-12 dB) to 10 (+17 dB)
Tech Info
Pack Profi les
Diagnostics
Sidetone Override
Battery DGs
Roaming
Choose Control Unit
Active Pairing
On/Off
Dual Pairing
Pairing