O P E R A T I N G M A N U A L
8 0 0 . 7 4 9 . 2 7 6 1
w w w . c o a c h c o m m . c o m
1 4
Control Unit Rear
A.
AC Power Connection
–
100–240V, 50/60 Hz 0.8A
B.
SYNC IN Port (RJ-45 or Fiber)
–
Allows the system to be synchronized with another X-System. Sync is
recommended when more than two unsynchronized X-System Antennas are operating in close proximity to one
another.
C.
RELAY Connection
–
Not currently used with X-System operation
D.
X-Net Ports (RJ-45 or Fiber)
–
The X-Net ports allow the Control Unit to connect to other X-System devices,
such as Antennas, forming a proprietary network design where all devices are part of a system configuration that
shares data, timing synchronization, and audio.
E.
2 WIRE Intercom Port (x 4)
–
The Intercom conference ports (1, 2, 3, and 4) connect the Control Unit to channels
A/B and C/D of the Wired Interface.
F.
4 WIRE Intercom Port (x 4)
–
Not currently used with X-System operation
G.
STAGE ANNOUNCE (SA)
–
Not currently used with X-System operation
H.
Auxiliary Audio Input (AUX IN)
–
Not currently used with X-System operation
I.
Auxiliary Audio Output (AUX OUT)
–
Not currently used with X-System operation
J.
Local Area Network (LAN) Port
–
The LAN port allows the Control Unit to be connected to a PC and X-Ware. See
the “Connecting X-Ware to Your CU” section on page 32 of this manual for more LAN connection information.
Figure 16: XCU-44 Rear View