Generators Continued
Refer to your operator’s manual for specific instructions. Below is a chart showing required periodic
maintenance as provided by Onan.
1- Before operating the set each day, or at least every 8 hours, check for oil and fuel leaks. Check exhaust system audibly and visually with generator
set running. Shut down the set and repair any leaks immediately. Replace corroded exhaust and fuel line components before leaks occur. Make
sure exhaust pipe extends beyond the perimeter of the RV.
2- Or once a year, whichever is first. Perform more often in extremely dusty conditions (i.e., check monthly, and change if dirty)..
3- Replace fuel filter at carburetor, clean screen at fuel pump .
4- Refer to Out-of-Service Protection if unit is to be stored.
5- Have your Onan service center perform.
6- First oil change during first year or 50 hours of operation, whichever is first.
7- During periods of non-use, exercise for 2 hours every 4 weeks.
8- Replace if necessary.
9- Perform more frequently if there are extended periods of non-use.
MISCELLANEOUS ELECTRICAL
GFI Receptacles
✔
Test all GFI receptacles monthly.
• Push in test button, the reset button should pop out.
• Push in reset button and it should hold. Replace receptacle if reset button does not hold and pops
out.
Breakaway Switch
✔
Inspect at beginning of camping season and prior to each trip and make sure it is securely fastened
to trailer.
✔
Have tested during brake system maintenance.
35
ELECTRICAL
General Inspection
X 1
Check Oil Level
X
Check Battery Electrolyte Level
X
Clean Out Spark Arrester
X
Clean Governor Linkage
X 2
Change Crankcase Oil and Oil Filter
X 2,6
Change Air Filter
X 2
Clean Carburetor & Combustion Chamber w/Onan “4C” Cleaner
X
Check Spark Plugs
X 4,8
Inspect and Clean Internally, Engine Combustion Chamber
X 5
Replace Fuel Filter (Gasoline) or Clean Fuel Filter (LPG)
X 3
Inspect and Pressure Test the LPG System
X 5,9
Adjust Carburetor
As Required 5
Check Generator Brushes
As Required 5
Clean Generator Set
As Required 5
Exercise Generator Set
As Required 5
Service These Items
After Each Cycle of Indicated Hours
8 hrs 50 hrs 150 hrs 300 hrs 500 hrs
Summary of Contents for Aurora
Page 4: ...2 ...
Page 10: ...8 ...
Page 14: ...12 ...
Page 16: ...14 ...
Page 18: ...16 ...
Page 20: ...18 ...
Page 22: ...20 ...
Page 24: ...22 ...
Page 26: ...24 ...
Page 28: ...26 ...
Page 30: ...28 ...
Page 42: ...40 ...
Page 46: ...44 ...
Page 50: ...48 ...
Page 52: ...50 ...
Page 55: ...53 MAINTENANCE CHARTS ...
Page 56: ...54 MAINTENANCE CHARTS ...
Page 57: ...55 MAINTENANCE CHARTS ...
Page 58: ...56 MAINTENANCE CHARTS ...
Page 59: ...57 MAINTENANCE CHARTS ...
Page 60: ...58 MAINTENANCE CHARTS ...
Page 70: ...68 TROUBLESHOOTING ...
Page 77: ...75 APPENDIX A POWER GEAR SLIDE OUT ROOM TOWABLES ...
Page 78: ...76 APPENDIX A POWER GEAR SLIDE OUT BEDROOM TOWABLES ...