5
(Unit : Inch)
Fig 1-8. The space clearance example
CAUTION
-
Install the unit in a dust-free room of low humidity and on a level concrete floor.
- Never install the unit on timbers or block. High humidity may result in electrical shorts and corrosion.
- Dust particles containing iron or sand may result in poor resistance of the motor and air-end damage.
- A ventilation fan should be provided to keep the ambient temperature 115℉ or lower.
- operation at ambient temperature of higher than 115℉ may cause compressor shutdown or severe
damage to the unit.
HEAT GENERATION & VENTILATION FAN CAPACITY
MODEL
CAPACITY
CHSA-7.5M
CHSA-10M
CHSA-15M
CHSA-20M
CHSA-25M
CHSA-30M
CAPACITY (Btu/h)
AIR VOLUME (cfm)
1165
1235
1900
2120
2330
2540
Note
1. The room ventilation capacity is based on :
(1) Compressor room Temperature rise which is controlled within the 9 .
℉
(2) Static pressure of ventilation air should be 0 inchWG.
2. Consult the distributor for more information on ventilation capacity when the air exhaust
duct is installed.
A
B
C
D
CHSA-7.5M
24
42
42
24
CHSA-10M
24
42
42
24
CHSA-15M
24
42
42
24
CHSA-20M
42
42
42
24
CHSA-25M
24
42
42
24
CHSA-30M
24
42
42
24
Summary of Contents for CHSA-10M
Page 31: ...27 AIR END NK40 ...
Page 33: ...29 AIR END NK60 ...
Page 34: ...30 Appendix B 1 PART LIST FOR MODEL CHSA 7 5M 1 2 ...
Page 35: ...31 1 PART LIST FOR MODEL CHSA 7 5M 2 2 ...
Page 36: ...32 2 PART LIST FOR MODEL CHSA 10M 1 2 ...
Page 37: ...33 2 PART LIST FOR MODEL CHSA 10M 2 2 3 PART LIST FOR MODEL CHSA 15M 1 2 ...
Page 38: ...34 3 PART LIST FOR MODEL CHSA 15M 2 2 ...
Page 39: ...35 4 PART LIST FOR MODEL CHSA 20M 1 2 ...
Page 40: ...36 ...
Page 41: ...37 4 PART LIST FOR MODEL CHSA 20M 2 2 ...
Page 42: ...38 C Wiring Diagram for Model CHSA 7 5 10 15 20M ...
Page 43: ...39 Appendix D 1 Outline Drawing for Model CHSA 7 5 10M ...