Precautions
1. Make sure the length of the pipe is as short as possible for less pressure drop and reduce
the number of connecting joints such as valve, elbow, etc.
2. Please install drain plug in the lower area of the pipe.
3. Please install bypass pipe on the compressor to facilitate maintenance.
4. There is a check valve installed inside the compressor. Do not install separate check valve in
the pipe. When installed, there can be an error in load-unload information.
5.
In cases with varying demand, it is desirable to install a separate tank.
6. As for the main piping, provide sloping for moisture damage. (About 1/100).
Please consult your distributor.