<Fig. 15>
8)
DISCHARGE PRESSURE CHECK
Using the compression pressure gauge, check if the pressure rises to the level set after the
operation. If the air tank pressure rises up to 114/140 PSI(8.0/9.9 Kg/cm
2
G), the operation stops
automatically. Figure inside () is high pressure specification.<Fig. 14>
9)
CHECK THE PRESSURE SWITCH OPERATION
Open the discharge ball valve and reduce the pressure and check to make sure if the product
operates automatically at 92/119 PSI(6.5/8.4 Kg/Cm
2
G). <Fig. 15>
10)
STOP
Press OFF button in the control area of the control box. Then, check and make sure if the
discharge pressure is 0PSI/cm2(g). Here, the sound of discharging compressed air is not a
sign of damage. <Fig. 16>
COAIRE, Div. of Quietside Corporation
14
<Fig. 14>
<Fig. 16>