Before you install the air compressor you should take the time to carefully read all the instructions contained in this
manual. Electricity and compressed air have the potential to cause severe personal injury or property damage. Before
installing, wiring, starting, operating or making any adjustments, identify the components of the air compressor
using this manual as a guide. The operator should use common sense and good working practices while operating
and maintaining this unit. Follow all procedures and piping accurately. Understand the starting and stopping
sequences. Check the safety devices in accordance with the following procedures contained in this manual.
Maintenance should be done by qualified personnel, accurately with proper tools. Follow the maintenance schedule
as outlined in the manual to ensure problem free operation after start up.
BEFORE INSTALLING THE COMPRESSOR OR PERFORMING
ANY MAINTENANCE READ THIS MANUAL CAREFULLY.
WARNINGS
COMPRESSED AIR AND ELECTRICITY ARE DANGEROUS. BEFORE DOING ANY WORK ON THIS UNIT, BE SURE THE
ELECTRICAL SUPPLY HAS BEEN SHUT OFF(LOCKED AND TAGGED) AND THE ENTIRE COMPRESSOR SYSTEM HAS
BEEN VENTED OF ALL PRESSURE.
1.
Do not remove the cover, loosen or remove any fittings, connections or devices when this unit is operating or
in operation. Hot liquid and air that are contained within this unit under pressure can cause severe injury or
death.
2. The compressor has high and dangerous voltage in the motor, the starter and control box. All installations
must be in accordance with recognized electrical procedure. Before working on the electrical system, ensure
that the system's power has been shut off by use of a manual disconnect switch. A circuit breaker or fuse
switch must be provided in the electrical supply line to be connected to the compressor. The preparation work
for installation of this unit must be done on suitable ground, maintenance clearance and lightning arrestors
for all electrical components.
3. Do not operate the compressor at a higher discharge pressure than those specified on the compressor
nameplate. If so an overload will occur. This condition will result in electric motor compressor shutdown.
4. Use only safety solvent for cleaning the compressor and auxiliary equipment.
5. Install a manual shut off valve(isolation type) in the discharge line for service work.
6. Whenever pressure is released through the safety valve during operation, it is due to excessive pressure in the
system. The cause of excessive pressure should be checked and immediately corrected.
7. Before doing any mechanical work on the compressor,
a)
Shut down the unit.
b) Electrically isolate the compressor by use of the manual disconnect switch in the power line to the unit.
Lock and tag the switch so that it cannot be operated.
c) Release all compressed air within the system and isolate the unit from any other sources of air.
8. Allowing the unit lubricants to enter into the plant air system must be avoided at all times. Air line separators,
which are properly selected and installed, can reduce any liquid carry-over close to zero.
9. Before starting the compressor, the maintenance instructions should be thoroughly read and understood.
10. After maintenance work is completed, covers must be securely closed.
11. For questions contact your distributor before proceeding.
SAFETY AND PRECAUTIONS
SAFETY AND PRECAUTIONS
Summary of Contents for CSOF-S3PL(H)
Page 8: ...COAIRE Div of Quietside Corporation 6 2 2 Compressor Outside View Fig 1 ...
Page 18: ...COAIRE Div of Quietside Corporation 16 5 COMPRESSOR STRUCTURE Fig 19 ...
Page 24: ...COAIRE Div of Quietside Corporation 22 8 WIRING DIAGRAM 8 1 CSOF S3 5PL H 11 ...
Page 25: ...COAIRE Div of Quietside Corporation 23 8 2 CSOF S3 5PL H 31 ...