14
4-3-3 Selection of Where to Install
Item
Description
Place
-
Do not install the compressor unit on the outside.
-
Please keep warm during the winter season, if you have to install on the outside.
Space
-
Keep the space of more than 31.5inch from the wall to facilitate the repair and
maintenance of the compressor
-
Do not place any object in front of the door.
Floor and
Foundation
-
The floor shall sufficiently holds the weight of the compressor.
-
The floor surface shall be flat with a gradient less than 1 degree to minimize
the vibration.
-
It is recommended to install the compressor 4inch above the floor, though
Coaire air compressor generates an insignificant amount of vibration.
Room
Temperature
-
Optimal ambient temperature is 32~104℉ during the operation.
-
Install the compressor at low temperature and moisture, if possible.
※ Each 18℉ increase of the inlet temperature reduces the efficiency of the
compressor by 3-4%.
Hazardous
Substances
-
Install the compressor at the place where there is the least noxious gas,
hazardous substance and dust. Those foreign substances may cause the damage
of the air compressor.
Electricity
-
The electric power shall have at least 150% of the reference margin.
-
The range of fluctuation in voltage shall be within ±10%.
Ventilation
-
A ventilation fan shall be installed to forcedly ventilate the room, if the room
temperature exceeds 18℉ more than the outside temperature in the summer.
-
For an exhaust duct, set the velocity at 5 m/s, and the static pressure at less than
5 mmAq.
-
Install a protective net on the exhaust outlet to prevent birds, rodents and
foreign substances from entering..
-
Place the inlet as low as possible.
[table 4-2] Requirements for Where to Install
INSTALLATION
Model
Air Volume
[ ft³/min = CFM ]
Hood Size
[ Inch x Inch ]
CSOF-M3PL(H), CSOF-M5PL(H)
1060
11.8” x 23.6”
CSOF-S8PL(H), CSOF-S10PL(H)
2120
15.8 “ x 31.5”
[ Table 4-1 ] Ventilation Fan Capacity