39
Low discharge pressure
- Clean the suction filter, and
replace, if necessary
No
9-2-4 No Compression
Airend is
damaged
- Check the rotation
- Check if there is any abnormal
noise
Yes
Failure of
controller
- Check the pipe for leakage
- Install an additional compressor if
the capacity is insufficient
No
Yes
- Check the function of a multi-unit
control
- Check the magnet and the output
of the controller
Yes
No
Start-Up
Request a service
No
9-2-5 Discharge Pressure Rise
Discharge Pressure Rise
Error message “High pressure” appears
Check the operation of the pressure
sensor
No
Yes
Failure of controller
Check the output of the controller
No
Failure of pressure
sensor
Safety valve is
activated
Pressure sensor or safety valve is
defective
Yes
No
Start-Up
Request a service
Excessive amount
of air used
Yes
Suction filter is
clogged
Yes
After eliminating the cause
After eliminating the cause
TROUBLESHOOTING