Recommended Fuels
Smokeless - Phurnacite Plus, Supacite, Centurion,
Coalite (Nuts), Maxibrite, Phurnacite,
Sunbrite (Doubles), Extracite, Pureheat,
Blazebrite, Taybrite, Anthracite (Large Nuts),
Welsh Dry Steam Coal (Large Nuts.
Selected Bituminous - Doubles, Trebles
PETROLEUM COKE MUST NOT BE USED.
The appliance user should check with their installer that
the chimney has been examined and confirmed for
soundness, the chimney has been swept prior to the
stove installation and is free of any obstructions.
The freestanding Severn Stove with boiler has been
approved by HETAS LTD, any may be used for any of the
following:-
1. Space heating and combined domestic hot water
supply and radiators.
2. Space heating and heating of pipes and radiators only.
NOTE: MOST TYPES OF LOGS AND BLOCKS MAY BE
USED PROVIDING THEY HAVE BEEN DRIED AND ARE
WELL SEASONED, IDEALLY SOFT WOODS SHOULD
BE BURNED IN THE DAYTIME AND HARD WOOD
OVERNIGHT.
WARNING: WET WOOD SHOULD NOT BE USED AS
CREOSOTE AND TAR-LIKE DEPOSITS FROM THE
WOOD ARE INCREASED TO A LEVEL WHICH CAN
GIVE RISE TO ADVERSE OPERATING CONDITIONS.
FUELS SHOULD BE STORED UNDER COVER.
NOTE: REFER PROBLEMS ABOUT FUEL SUITABILITY
OR QUALITY TO FUEL SUPPLIER.
IMPORTANT: FUELS SHOULD BE OF THE CORRECT
SIZE FOR THE STOVE OTHERWISE THE APPLIANCE
WILL NOT GIVE A SATISFACTORY PERFORMANCE.
a. Open the firedoor, Fig. 1
b. Lay a liberal supply of wood/paper on the grate
together with a small quantity of fuel and light the
paper. Alternatively place four firelighters equally
spaced across the grate. Cover with fuel and light.
c. Close and lock both firedoors. See Fig. 1 and set the
thermostat knob to high (No.8) Fig. 2.
d. With the fire established open the firedoors, fill firebox
up to the top of the front firebar and sloping upwards
to the back.
e. Close and lock the firedoors. Fig. 1 with the operating
tool.
THIS IS ESSENTIAL TO ACHIEVE CONTINUAL
SAFE RUNNING EFFICIENT OPERATION OF THE
STOVE.
f. Adjust the thermostat knob, Fig. 2 to give the desired
rate of burning.
g. Replace operating tool on its support cradle when not
in use. See Fig. 3.
Bituminous Fuel
If bituminous fuel is to be burnt the following procedure
MUST
be adhered to:-
1. Fuel must be refuelled to the maximum limit ie. at 30
˚
incline from the front edge of the top firebar.
TO LIGHT THE FIRE
2
Fig. 1
Fig. 2
Fig. 3
Fig. 4