5
Use a damp sponge or proprietory brand of cleaner to clean
outside of stove.
DO NOT CLEAN THE STOVE WHEN IT
IS HOT
.
With use the inside face of the glass doors may become
coated with dust and deposits. To clean glass, allow to cool
and then wipe it with a damp cloth and polish with a dry
one.
1. Always use a qualified service engineer when service is
required.
2. An inspection of both firedoor seals should be made
every heating season and replaced if necessary.
When not in use remove all the fuel and ashes from the
firebox. Leave the thermostat knob at a high setting (No.8)
to allow a constant stream of air to pass through the stove.
If the fire is not used when there is a danger of frost, the
whole system should be drained.
Never the light the fire if the water system is frozen.
Replace the individual bottomgrate bars as and when they
burn to ensure sufficient burning.
Replacement parts if required are available through your
local stockist.
APPLIANCE CLEANING - GENERAL
SERVICING
PRECAUTIONS
SPARE PARTS
Severn Stove with Boiler
Part No.
Description
No. Required
HS5M-S413A
Front Firebar (Upper)
1
1 set
HS5M-S413
Front Firebar (Upper)
1
HS5B-D358
Bottomgrate (Upper)
7
1 set
HS5B-D353
Bottomgrate (Lower)
8
HS1M400000
Ashpan - LH
1
HS1M400001
Ashpan - RH
1
HS5-17720
Throat Plate
1
HS5M0-30825
Firedoor Glass Panels
2
1 set
RS4T 46070
Boiler Thermostat
1
HS4M 33984
Boiler Thermostat Knob
1