background image

TABLE OF CONTENTS 

Letter from Coast Spas Manufacturing Inc. 

Page

 

Registering your spa

Page

 

Table of contents

Page

 

Basic information

Page

 

Important safety instruction & Glossary of terms

Page

 

6

-8

Preparation, set-up and location for your new spa

Page

 

8

 

Special spa series general layout

Page

 

9

Special series spa collection

Page

 

10

 

Special series spa features

Page

 

11

Spa start-up guide

Page

 

12

 

Spa care guide

Page

 

13-14

Basic installation and configuration guidelines

Page

 

15-16

Spa maintenance procedures

Page

 

1

6

 

Water quality, diverter , and jet maintenance

Page

 

17

Troubleshooting guides

Page

 

1

9

-

21

Draining and winterizing

Page

 

22

 

Spa controls

Page

 

23-24

Ozone Instructions 

Page

 

31

 

Service Log

Page

 

32

-

33

OWNER’S MANUAL 

2022 

SPECIAL SERIES

Special Series Spa Jet Operations

Page

 

2

5

-2

9

Special Series Spa 

Specifications

Page

 

30

Summary of Contents for President's Club Special Freedom

Page 1: ...URBAN FREEDOM 2022 SPECIAL SERIES ELEMENT Coast Spas Manufacturing 6315 202 Street Langley BC Canada 604 514 8111 info coastspas com www coastspas com ...

Page 2: ...2 OWNER S MANUAL 2022 SPECIAL SERIES ...

Page 3: ...a you will need the spa serial number Picture below will help you locate the serial number on your spa OWNER S MANUAL 2022 SPECIAL SERIES Address __________________________________________________________________________________ Email _________________________ Contact Spa Serial number Delivery Date ________________________ ________________________ ________________________ Purchase Date __________...

Page 4: ...collection Page 10 Special series spa features Page 11 Spa start up guide Page 12 Spa care guide Page 13 14 Basic installation and configuration guidelines Page 15 16 Spa maintenance procedures Page 16 Water quality diverter and jet maintenance Page 17 Troubleshooting guides Page 19 21 Draining and winterizing Page 22 Spa controls Page 23 24 Ozone Instructions Page 31 Service Log Page 32 33 OWNER ...

Page 5: ...n the length of the run The electrical circuit must be installed by a certified electrician and approved by a local building or electrical inspector Surface Transport Your new spa has left the factory cleaned and polished and ready to begin operation after passing our many quality and operational tests However depending on your location in the world your spa may have spent days or even weeks in tr...

Page 6: ...To Reduce the Risk of Injury The water in a spa should never exceed 104 F 40 C Water temperatures between 100 F 38 C and 104 F 40 C are considered safe for a healthy adult Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy pregnant or p...

Page 7: ... tie downs or actual locks will prevent access to the spa CAUTION For exercise the water should not exceed 90 F 32 C AIR CONTROL Mounted generally on the lip of the spa it induces warm air from the equipment enclosure into the jet stream through venturi action WATER DIVERTER The large diverter is used to divert water to various seats in the spa FILTER AIR RELIEF VALVE Located on top of dome filter...

Page 8: ...d for foot and leg massage PREPARATION SET UP AND LOCATION FOR YOUR NEW SPA You want to keep in mind how you intend to use the spa and plan the location accordingly How close is the spa from the exit or entrance to your house consider the cold weather Is the path to your spa clean of debris sand grass so as not to track into the spa Is there protection from wind inclement weather Can neighbors or ...

Page 9: ...y Jets 5 Air Control 6 Spa Lights 7 Water Diverter 8 Pillow 9 Cluster Jets 10 Hydro Cyclonic Water Filtration System 11 Suction 12 Spa Drain 13 3 Spa Light 14 Volcano Jet 9 DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information pl...

Page 10: ...nual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com President s Club Special Freedom Special Element Bench Special Element Lounge Urban Special ...

Page 11: ...es Dual 3 Blade Adjustable Waterfalls Positioned to flow onto your shoulders to provide a gentle relaxation sensation Provides the soothing sound of running water When coupled with an LED Lighting System both waterfalls are vibrantly lit with a spectrum of beautiful colors Each waterfall is independently adjustable SPA COMFORTS Plush Headrests Beverage Holders Anti Slip Textured Floor Ergonomic Se...

Page 12: ......

Page 13: ... pillow firmly which will insert the plug back into the receptacle Proper water chemistry must be maintained Your spa pillows are easily and quickly damaged when exposed to unbalanced spa water If you suspect that your chemicals may be unbalanced remove your pillows immediately until the water has been restored to suggested conditions Do not sit on the pillows Do not pull on the pillows Pillows sh...

Page 14: ... for a minimum of 30 minutes to ensure that the chemical gas off can escape from the spa You are required to keep the spa covered at all time when not in use to protect the shell from harmful UV rays A covered spa will use less electricity when maintaining the desired water temperature See the manual that comes with the cover for proper mounting of the cover locks The cover should remain locked at...

Page 15: ...0VAC Depending on the model of spa it will require either a 40 Amp 50 Amp or 60 Amp dedicated circuit breaker GFCI with the proper wire size based on the length of the run The electrical circuit must be installed by a certified electrician and approved by a local building or electrical inspector Use minimum 6AWG copper conductors only Torque field connections between 21 and 23 in lbs Readily acces...

Page 16: ...chased from your local dealer TOP LOAD FILTERS Turn power OFF at the breaker Loosen air relief valve then remove retainer ring Pull filter lid straight up to remove Do not twist or pull the filter lid up on an angle This could cause damage to the filter canister especially in freezing conditions Remove filter cartridge and clean with a garden hose and a high pressure nozzle Periodically you may ne...

Page 17: ... acid to balance the pH as it could severely damage the spa shell Sanitizer Chlorine or Bromine To destroy bacteria and organic compounds in the spa water by breaking them down into non harmful levels which get filtered out A sanitizer must be used regularly either chlorine or bromine Sanitizing your spa water is the most important spa maintenance you can do for yourself Total Alkalinity TA is the...

Page 18: ...nd potential damage to the plumbing It is the responsibility of the customer to regularly perform the maintenance procedures To clean and maintain optimum jet functions follow the maintenance instructions below LAMINAR FLOW JET MAINTENANCE INSTRUCTIONS 1 Rotate counter clock wise and pull out the jet body Picture 1a and 1b 2 Using clean piece of cloth remove the dust particles or debris Picture 2 ...

Page 19: ...ains Total alkalinity is too low pH is too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Cloudy Water Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water Algae Growth pH is too high Sanitizer is too low Adjust...

Page 20: ...Dealer Pump running constantly will not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact yo...

Page 21: ...tended periods of time in cold weather cold wind Hot tub is wired for 110V and jets are on Put cover back onto hot tub and allow for heat to regenerate Call your dealer if temperature does not increase Hot tubs wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in ...

Page 22: ... the following winterizing procedures if you are not completely comfortable with them Ensure that you have fully drained the spa Refer to the DRAINING YOUR SPA section After draining your spa may still have water remaining in the equipment and plumbing fittings Disconnect the hand tightened union fittings going to and from the jet pumps Be careful not to lose the O rings between the unions and pum...

Page 23: ... The ozone generator if installed will activate anytime low speed is run ning AUX PUMP 2 If an additional pump or blower is installed Press Aux to turn the device on If your additional device is a dual speed pump pressing Aux again will activate the pumps high speed Pressing Aux again will turn off the device pump LIGHT Press Light to operate the spa light Turns off after 4 hours If your hot tub i...

Page 24: ...ion If flashing by itself spa is shut down If the problem persists contact your dealer or service organization HL A significant difference between temperature sensors has been detected This could indicate a flow problem If the water level is normal make sure all pumps have been primed If problem persists contact your dealer or service organization LF Persistent low flow problems Displays on the fi...

Page 25: ...M 40 NO DOME HIGH PROFILE DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com ...

Page 26: ... 40 WITH DOME HIGH PROFILE DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com ...

Page 27: ... BENCH 40 LOW HIGH PROFILE DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com ...

Page 28: ...LOUNGE 40 LOW HIGH PROFILE DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com ...

Page 29: ...LUB URBAN LOW PROFILE DISCLAIMER At the time of print this manual is accurate in its information Coast Spas reserves all the rights to change modify any spa designs and or features without notification To check on updates or for other information please visit www coastspas com ...

Page 30: ... x 92 x 40 1666 440 585 1291 2251 4963 Special Element Bench 5 212 x 212 x 92 83 5 x 83 5 x 36 1210 320 420 925 1630 3594 Special Element Lounge 5 212 x 212 x 92 83 5 x 83 5 x 36 1210 320 420 925 1630 3594 Special Urban 4 168 x 212 x 92 66 x 83 5 x 36 890 235 294 647 1184 2610 OWNER S MANUAL 2022 SPECIAL SERIES SPECIAL SPA SEPECIFICATIONS 30 ...

Page 31: ...ammed filter cycles and pump 1 operation Verify that the green light on the Ozone turns on when activated Check the spa drain at the bottom of the spa to verify that small ozone bubbles are coming out Verify that one way check valve is installed on the ozone tubing and it is working as intended ...

Page 32: ..._________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ __________...

Page 33: ..._________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ _____________________________________________________________ __________...

Page 34: ...WORLD S BEST BUILT SPAS ...

Reviews: