13
DRAIN VALVE:
Used in draining of the spa. Normally locat-
ed in the equipment area.
EQUIPMENT ENCLOSURE:
An enclosure that houses the
control box, pump(s) and other electrical components.
FILTER:
The filter cleans the spa by passing water through
a filter cartridge where debris and impurities are removed. Top
load filter means the filter cartridge is accessible through the top
of the spa. Front access skimmer means cartridge is accessed
through door of skimmer.
FLOOR DRAIN:
The floor drain is covered by a grate-type
cover and is utilized when draining the spa. It also acts as the
return for the ozonator. You will see bubbles emitted from this
drain, which is the result of water mixing with the ozone output.
GATE VALVES:
Red with a grey handle is located at the
inlet and outlet of the pumping system. Used while servicing the
spa equipment, the valves open or close the water flow to the
equipment. To remain open for normal use, turn fully counter-
clockwise.
KNIFE VALVES:
A white “T”-handled valve, same functions as
Gate valve (see above), except to open them you pull up on
handle.
HEATER:
The electronically controlled heater raises the
temperature of the spa to the desired setting.
LEDs:
LEDs and their special lenses can be used to achieve
the desired mood lighting in the spa and spa jets.
SKIMMER:
This is the rectangular outlet at the water level.
The skimmer removes surface debris to the filter. The water
level in the spa should be kept ½ to ¾ up on the skimmer for
optimum operation.
SUCTION FITTING:
During operation of the equipment, the
suction works in conjunction with the skimmer to draw water
from the bottom of the spa through the filter, keeping the spa
sparkling clean.
NECK JET:
Direction-controllable jet for soothing neck mas-
sage.
ADJUSTABLE CLUSTER JET:
Our adjustable, high-intensity
hydrotherapy jet.
DIRECTIONAL JET:
Provides a straight flow for a therapeu-
tic massage
ROTATIONAL JET:
Provides a Uni-directional circular thera-
peutic massage.
MASSAGE JET:
Delivers massage in staccato bursts over a
narrow, focused area.
VOLCANO/WHIRLPOOL JET:
high-output jet designed for foot
and leg massage.
LAMINAR FLOW WATER FEATURE:
A thin stream of water
that arcs from the spa lip.
BASIC INSTALLATION AND CONFIGURATION GUIDELINES
Warning! Qualified Technician Required for Service and
Installation
Use minimum 6AWG copper conductors only. Torque field con-
nections between 21 and 23 in lbs. Readily accessible discon-
OWNER’S MANUAL
2020
necting means to be provided at time of installation. Permanently
connected power supply.
Connect only to a circuit protected by a Class A Ground Fault
Circuit Interrupter (GFCI) or Residual Current Device (RCD)
mounted at least 5’ (1.52M) from the inside walls of the spa/hot
tub and in line of sight from the equipment compartment.
CSA ENCLOSURE: TYPE 2
Refer to Wiring Diagram inside the cover of the control enclo-
sure.
Refer to Installation and Safety Instructions provided by the spa
manufacturer.
Warning:
People with infectious diseases should not use a
spa or hot tub.
Warning:
To avoid injury, exercise care when entering or
exiting the spa or hot tub.
Warning:
Do not use a spa or hot tub immediately follow-
ing strenuous exercise.
Warning:
Prolonged immersion in a spa or hot tub may be
injurious to your health.
Warning:
Maintain water chemistry in accordance with the
Manufacturers instructions.
Warning:
The equipment and controls shall be located no
less than 1.5 meters horizontally from the spa or hot tub.
WARNING! GFCI OR RCD PROTECTION.
The Owner should test and reset the GFCI or RCD on a regular
basis to verify its function.
WARNING! SHOCK HAZARD! NO USER SERVICEABLE PARTS.
Do not attempt service of this control system. Contact your deal-
er or service organization for assistance. Follow all owner’s man-
ual power connection instructions. Installation must be performed
by a licensed electrician and all grounding connections must be
properly installed.
• Disconnect the electric power before servicing. Keep access
door closed.
CSA COMPLIANCE
Caution:
Test the ground fault circuit interrupter before each use of the
spa.
Read the instruction manual.
Adequate drainage must be provided if the equipment is to be
installed in a pit.
For use only within an enclosure rated CSA Enclosure 3.
Connect only to a circuit protected by a Class A ground fault
circuit interrupter or residual current device.
To ensure continued protection against shock hazard, use
only identical replacement parts when servicing.
Install a suitably rated suction guard to match the maximum
flow rate marked.
Warning:
Water temperature in excess of 38°C may be injurious to
your health. Disconnect the electrical power before servicing.
Summary of Contents for Swim 2100VE
Page 1: ...1 ...
Page 3: ...3 ...
Page 4: ...4 ...
Page 5: ...5 ...
Page 32: ...32 OWNER S MANUAL 2020 ...