background image

 

18 

 

PRIMING THE PUMPS 

As soon as the Priming Mode screen appears on the panel, select the 
“Jets 1” button once to start Pump 1 in low-speed and then again to 
switch to high-speed. Also, select the other pumps, to turn them on. The 
pumps should be running in high-speed to facilitate priming. If the pumps 
have not primed after 2 minutes, and water is not flowing from the jets in 
the spa, do not allow the pumps to continue to run. Turn off the pumps 
and repeat the process. Note: Turning the power off and back on again 
will initiate a new pump priming session. Sometimes momentarily turning 
the pump off and on will help it to prime. Do not do this more than 5 
times. If the pump(s) will not prime, shut off the power to the spa and call 
for service. Important: A pump should not be allowed to run without prim-
ing for more than 2 minutes. Under NO circumstances should a pump be 
allowed to run without priming beyond the end of the 4-5 minute priming 
mode. Doing so may cause damage to the pump and cause the system 
to energize the heater and go into an overheat condition. 

EXITING PRIMING MODE 

The system will automatically enter the normal heating and filtering at 
the end of the priming mode, which lasts 4-5 minutes. You can manually 
exit Priming Mode by pressing the “Exit” button on the Priming Mode 
Screen. Note that if you do not manually exit the priming mode as de-
scribed above, the priming mode will be automatically  terminated after 4
-5 minutes. Be sure that the pump(s) have been primed by this time. 
Once the system has exited Priming Mode, the top-side panel will dis-
play the Main Screen, but the display will not show the temperature yet, 
as shown below. This is because the system requires approximately 1 
minute of water flowing through the heater to determine the water tem-
perature and display it. 
 

 

SPA BEHAVIOR 

PUMPS 

On the Spa Screen, select a “Jets” button once to turn the pump on or 
off, and to shift between low- and high-speeds if equipped. If left run-
ning, the pump will turn off after a time-out period. 

OWNER’S MANUAL 

2017 

NON-CIRC SYSTEMS 

The low-speed of pump 1 runs when the blower or any other pump is on. 
If the spa is in Ready Mode, Pump 1 low may also activate for at least 1 
minute every 30 minutes to detect the spa temperature (polling) and then 
to heat to the set temperature if needed. When the low-speed turns on 
automatically, it cannot be deactivated from the panel, however the high 
speed may be started. 

CIRCULATION PUMP MODES 

If the system is equipped with a circ pump, it will be configured to work in 
one of three different ways: 
 

1. The circ pump operates continuously (24 hours) with the exception 
of turning off for 30 minutes at a time when the water temperature 
reaches 3°F (1.5°C) above the set temperature (most likely to happen 
in very hot climates). 
2. The circ pump stays on continuously, regardless of water  
temperature. 
3. A programmable circ pump will come on when the system is check-
ing temperature (polling), during filter cycles, during freeze conditions, 
or when another pump is on. The specific Circulation Mode that is used 
has been determined by the Manufacturer and cannot be changed in 
the field. Other device options may be available, like Blower, Light, 
Mister, etc. 

FILTRATION AND OZONE 

On non-circ systems, Pump 1 low and the ozone generator will run dur-
ing filtration. On circ systems, the ozone will generally run with the circ 
pump, but can be limited to filtration cycles. The system is factory-
programmed with one filter cycle that will run in the evening (assuming 
the time-of-day is properly set) when energy rates are often lower. The 
filter time and duration are programmable. 

 

A second filter cycle can be 

enabled as needed. At the start of each filter cycle, the water devices like 
blower, mister device (if these exist) and other pumps will run briefly to 
purge the plumbing to maintain good water quality. 

FREEZE PROTECTION 

If the temperature sensors within the heater detect a low enough tem-
perature, then the water devices automatically activate to provide freeze 
protection. The water devices will run either continuously or periodically 
depending on conditions. In colder climates, an optional freeze sensor 
may be added to protect against freeze conditions that may not be 
sensed by the standard sensors. Auxiliary freeze sensor protection acts 
similarly except with the temperature thresholds determined by the 
switch. See your dealer for details.

 

CLEAN-UP CYCLE (OPTIONAL) 

When a pump or blower is turned on by a button press, a clean-up cycle 
begins 30 minutes after the pump or blower is turned off or times out. 
The pump and the ozone generator will run for 30 minutes or more, de-
pending on the system. On some systems, you can change this setting.  

 

 

Summary of Contents for Wellness Spas

Page 1: ...1 VERSION 01142016 Wellness Spas by Coast Spas Manufacturing Inc 6315 202 Street Langley BC Canada 604 514 8111 info coastspas com www coastspas com ...

Page 2: ...e 6 Filter Maintenance Page 7 Water Quality Maintenance Page 7 Water Clarity Troubleshooting Page 9 Product Care Guide Page 10 Glossary of Terms Page 11 12 Basic Installation and Configuration Guidelines Page 12 Troubleshooting Guide Page 13 14 Spa Controls Page 15 34 Touchscreen Control Panel Page 15 24 Wellness IV Control Panel Page 25 26 Wellness Color Screen Controls Non touch Page 27 34 Spa P...

Page 3: ...3 ...

Page 4: ...4 ...

Page 5: ...y of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a hot tub CAUTION Risk of Hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the OWNER S MANUAL 2017 normal body temperature of 98 6 F 37 C The symptoms of hyperther mia include drowsiness lethargy and an increas...

Page 6: ...el surface so the spa weight is supported uniformly We recommend no less than a 3 93 mm thick concrete slab Wood decking or balconies must be con structed to support 150 pounds per square foot 730 kg m Refer to local and current building codes in your area Consult an engineer for live loads in your area Should your new spa need to go through a gate the opening should be a minimum of 48 inches and ...

Page 7: ...pply a light film of silicone lubricant to the o ring Do not use a petroleum based lubri cant as it could damage the o ring Consult your dealer to purchase suitable lubricant Place clean Cartridge in filter canister Replace filter lid and re tighten retaining ring finger tight only OWNER S MANUAL 2017 NOTE Make sure the o ring is on the air relief valve and is finger tight prior to starting the pu...

Page 8: ...sening the need for pH balancing If the TA is too low the pH level will fluctuate rapidly from high to low If the TA is too high the pH will tend to be too high and will be very difficult to bring back down Calcium Hardness This is a measurement of dissolved calcium in the water Calcium will help control the corrosive nature of the spa s water WARNING Never store chemicals inside the equipment are...

Page 9: ... low pH is too low High metal content in water Adjust alkalinity Adjust pH Use stain and scale product Cloudy Water Poor filtration pH is too high Hardness is too high Total alkalinity is too high Suspended particles Clean filter cartridge Adjust pH Adjust hardness Adjust total alkalinity Drain and refill spa water Algae Growth pH is too high Sanitizer is too low Adjust pH Shock spa with sanitizer...

Page 10: ...ediately until the water has been restored to suggested conditions Do not sit on the pillows OWNER S MANUAL 2017 Do not pull on the pillows Pillows should be cleaned using a soft cloth and mild soap then wiped with a conditioner We recommend that pillows be washed each time you drain you spa HOT TUB INTERIOR Your hot tub has a fiberglass reinforced acrylic shell Generally dirt and stains will not ...

Page 11: ... the fluid used in cigarette lighters Use sparingly then immediately apply conditioner to that area GLOSSARY OF TERMS AIR CONTROL VALVE Mounted generally on the lip of the spa it in duces warm air from the equipment enclosure into the jet stream through venturi action WATER DIVERTER VALVE The large diverter is used to divert water to various seats in the spa OWNER S MANUAL 2017 ON OFF DIVERTER VAL...

Page 12: ...t use a spa or hot tub Warning To avoid injury exercise care when entering or exiting the spa or hot tub Warning Do not use a spa or hot tub immediately following strenuous exercise Warning Prolonged immersion in a spa or hot tub may be injurious to your health Warning Maintain water chemistry in accordance with the Manufac turers instructions Warning The equipment and controls shall be located no...

Page 13: ...Pump running constantly will not turn off Filter cycle set to 24 hours Problem with the circuit board Turn off 24 hour filtration Turn power off at GFCI and contact your Dealer Pump will not turn on GFCI tripped Motor has overheated Not plugged in Damaged plug Seized motor Blown fuse Motor vent is blocked Reset the GFCI Let cool for 1 hour Plug in to the board Contact your Dealer Contact your Deal...

Page 14: ...periods of time in cold weather cold wind Hot tub is wired for 110V and jets are on Put cover back onto hot tub and allow for heat to regenerate Call your dealer if temperature does not increase Hot tubs wired for 110V only have enough power to heat or operate pumps Turn off jets to power heater PUMPS WILL NOT PRIME PROBABLE CAUSE RECOMMENDED ACTION Pump on but no water flow Air trapped in pump No...

Page 15: ...vert to the main screen after 30 sec onds of no activity OWNER S MANUAL 2017 The only item that can be changed on the left side of the Main Screen is the Set Temperature Touch either the set temperature line or the water temperature to go to the Set Temperature screen MESSAGES At the bottom of the screen messages may appear at various times Some of these messages must be dismissed by the user THE ...

Page 16: ...ave changed the value on that screen If the screen times out due to no activity it will act like Cancel When you see only this button whether it is labeled or not it means Back or Exit It appears on editing screens before you have changed any value as well as on all other screens OWNER S MANUAL 2017 PAGE UP DOWN If an Up or Down button is shown and pressed when in a Menu List the list can be scrol...

Page 17: ...il the heater pump has been running for a minute or two When the heater pump has come on automatically for example for heating you can switch between low speed and high speed but you cannot turn the heater pump off OWNER S MANUAL 2017 CIRCULATION MODE If the spa is configured for 24HR circulation the heater pump generally runs continuously Since the heater pump is always running the spa will maint...

Page 18: ...re polling and then to heat to the set temperature if needed When the low speed turns on automatically it cannot be deactivated from the panel however the high speed may be started CIRCULATION PUMP MODES If the system is equipped with a circ pump it will be configured to work in one of three different ways 1 The circ pump operates continuously 24 hours with the exception of turning off for 30 minu...

Page 19: ... may be manufactured with Circ Pump settings that allow programming filtration cycle duration Some circ Modes are pre programmed to operate 24 hours a day and are not programmable Refer to the spa manufacturer s documentation for any Circ Mode details PURGE CYCLES In order to maintain sanitary conditions as well as protect against freez ing secondary water devices will purge water from their respe...

Page 20: ...t says On or Panel if it says On than press in the middle of the screen for at least 5 seconds OWNER S MANUAL 2017 SCENES WHAT ARE SCENES Scenes are stored combinations of equipment states For example if you want to have Pump 1 at high speed and Pump 2 at low speed and the Light ON you could store that in a Scene and recall this combination at any time STORING A SCENE Press a Scene number and hold...

Page 21: ...0XX is a Message Code Codes like this will be seen in the Fault Log ADDITIONAL SETTINGS PREFERENCES The Preferences Menu allows the user to change certain parameters based on personal preference TEMP DISPLAY Change the temperature between Fahrenheit and Celsius TIME DISPLAY OWNER S MANUAL 2017 Change the clock between 12 hr and 24 hr display REMINDERS Turn the reminder messages like Clean Filter O...

Page 22: ...e GFCI with its own test button Restore power to the spa and repeat the GFCI Trip Test Once the GFCI is tripped by the test reset the GFCI and the spa will operate normally from that point You can verify a successful test by navigating to the above menu Passed should appear after the Reset line is selected on the GFCI screen WARNING On those systems that automatically test the GFCI within 1 to 7 d...

Page 23: ...for Service MISCELLANEOUS MESSAGES COMMUNICATIONS ERROR The control panel is not receiving communication from the System Call for Service TEST SOFTWARE INSTALLED The Control System is operating with test software Call for Service OWNER S MANUAL 2017 F OR C IS REPLACED BY T The Control System is in Test Mode Call for Service M0XX is a Message Code Codes like this will be seen in the Fault Log SYSTE...

Page 24: ...pter GFCI or Residual Current Device RCD mounted at least 5 1 52M from the inside walls of the spa hot tub and in line of sight from the equipment compartment OWNER S MANUAL 2017 CSA ENCLOSURE TYPE 2 Refer to Wiring Diagram inside the cover of the control enclosure Refer to Installation and Safety Instructions provided by the spa manufacturer Warning People with infectious diseases should not use ...

Page 25: ...ub is equipped with a multicolor lighting package then pressing the Light button consecutively will toggle the lights through different colors modes OWNER S MANUAL 2017 MODE Mode is changed by pressing Temp then either Warm or Cool Standard Mode maintains set temperature St will be displayed mo mentarily when you switch into Standard Mode Economy Mode heats the spa to the set temperature only duri...

Page 26: ...a temporary condition If flashing by itself spa is shut down If the problem persists contact your dealer or service organization HFL HL A significant difference between temperature sensors has been detected This could indicate a flow problem If the water level is normal make sure all pumps have been primed If prob lem persists contact your dealer or service organization LF Persistent low flow prob...

Page 27: ... OWNER S MANUAL 2017 NAVIGATION Navigating the entire menu structure is done with the 5 buttons on the control panel When a text item changes to white during navigation that indicates the item is selected for action Operating or changing a selected item is generally done with the center or Select button The only item that can be changed on the left side of the Main Screen is the Set Temperature Pr...

Page 28: ...s where all programming and other spa behaviors are controlled This screen has several features that can be acted on directly These features include Temp Range Heat Mode and Invert Panel When one of these items is highlighted the Select Button is used to toggle between two settings All other menu items with an arrow point ing to the right go to another level in the menu PRESS AND HOLD If an Up or ...

Page 29: ...low flow or no flow conditions Nothing comes on auto matically but the pump s can be energized by selecting the Jet but tons If the spa has a Circ Pump it can be turned on and off by press ing the Circ Pump button during Priming Mode In addition if the spa has a Circ Pump it can be activated by pressing the dedicated Light OWNER S MANUAL 2017 button during Priming Mode Manually exit Priming Mode b...

Page 30: ...at will run in the evening assuming the time of day is properly set when energy rates are often lower The filter time and duration are programmable A second filter cycle can be enabled as needed FREEZE PROTECTION If the temperature sensors within the heater detect a low enough tem perature then the water devices automatically activate to provide freeze protection The water devices will run either ...

Page 31: ...ess RESTRICTING OPERATION The control can be restricted to prevent unwanted use or temperature adjustments Locking the Panel prevents the controller from being used but all automatic functions are still active Locking the Settings allows Jets and other features to be used but the Set Temperature and other programmed settings cannot be adjusted Settings Lock allows access to a reduced selection of ...

Page 32: ...or that item is displayed at the bottom of the screen Software ID SSID Displays the software ID number for the System OWNER S MANUAL 2017 System Model Displays the Model Number of the System Current Setup Displays the currently selected Configuration Setup Number Configuration Signature Displays the checksum for the system configuration file Heater Wattage as Configured in Software Displays a heat...

Page 33: ...eded M0XX is a Message Code Codes like this will be seen in the Fault Log Some messages can be reset from the panel Messages that can be reset will appear with a right arrow at the end of the message Press the message text to reset the message SENSOR RELATED MESSAGES SENSORS ARE OUT OF SYNC M015 The temperature sensors MAY be out of sync by 3 F Call for Service OWNER S MANUAL 2017 SENSORS ARE OUT ...

Page 34: ...is to verify its reliability Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper func tion CHANGE THE WATER May appear on a regular schedule i e every 90 days Change the water in the spa on regular basis to maintain proper chemical balance and sanitary conditio...

Page 35: ... pull firmly towards your body to release the Panel Clips Ensure not to pull too hard as you could potentially break the clips Illustration 2 3 After releasing the clips lower the panel to the ground If your Spa is equipped with an Obsidian Display there will be three wires to disconnect Illustration 3 RE INSTALLING THE PANEL 1 Hold the bottom edge of the panel and insert the top edge under the li...

Reviews: