WHAT DO THE VARIOUS LED SIGNALS MEAN?

The four LED segments of the 'ekey dLine fingerprint scanner' signal the different operation modes as well as error 

cases. Different light colors are used: Blue, yellow, green and red. These also indicate certain scenarios by means of 
different intervals in which they light up.

One blue illuminated LED segment and one blue flashing LED segment: 

If the top left LED segment is continuously illuminated blue, while the top right LED segment flashes blue, the 

connection to the local network is being established.

Two blue illuminated segments and one blue flashing LED segment: 

If both top LED segments are continuously illuminated blue, while the bottom-right LED segment flashes blue, the 

connection to the 'ekey bionyx app' is being established.

16

BLU-e Fitting Guide

Summary of Contents for BLU-e

Page 1: ...BLU e FITTING GUIDE AND INSTRUCTION MANUAL FITTING GUIDE ...

Page 2: ...list Wiring diagram Mounting plate control unit relay Connecting components wiring User Instructions First steps System Back up very important How to clean the scanner unit Information What do the LED colour signals mean QR Codes for Ekey website for further information LIST OF CONTENT 1 2 3 3 4 5 6 7 8 9 12 13 14 15 16 19 20 ...

Page 3: ...d information and troubleshooting please refer to the manufacturer s website via the links below We advise you get a qualified electrician to wire up the system wiring diagrams are shown within the wiring diagram section on page 5 and 6 of this document QR CODES RISK OF ELECTRIC SHOCK DAMAGE TO THE SYSTEM IF INSTALLED INCORRECTLY Wiring diagrams Customer training Mounting instructions dLine FAQs D...

Page 4: ...CX BLU E CT2 Cable Transfer Unit ML E EMTR Electric Motor Unit fits to locks ML120 ML3120 and ML480 Below is a list of components you will receive with your Blu e Biometric Pull Handle Kit These components will include all the entry system and electrical components you need to work with your door lock PLEASE NOTE This kit does not include the lock or keeps these are purchased separately BLU E HAB1...

Page 5: ... authorised to carry out electrical installation work on mains systems Property damage in the event of incorrect mounting and wiring The system devices are operated using electricity They could be destroyed if they are mounted and wired incorrectly Mount and wire the system devices correctly before connecting the power This wiring diagram is not subject to updating We reserve the right to make tec...

Page 6: ... LOCK CONNECTION TO THE CONTROL UNIT CONNECTION TO THE ELECTRICAL INSTALLATION PIN COLOR DESCRIPTION Green Switching impulse Brown GND White VDC PIN COLOR DESCRIPTION 4 3 Green Switching impulse 2 Brown GND 1 White VDC See connection configuration of the motorised lock manufacturer Potential free request to exit button for manual door opening Each unused core must be insulated separately 4 3 2 1 6...

Page 7: ...nt IP rating IP40 connector IP67 Temperature from 20 C to 75 C These Mounting instructions are not subject to updating We reserve the right to make technical modifications and change the product s appearance any liability for errors and misprints is excluded NOTICE MOUNTING INSTRUCTIONS EKEY DLINE CABLE TRANSFER CX BLU E CT2 LIT FG BLU e Dimension Milling dimensions for mounting into solid hollow ...

Page 8: ...2 mm 17 mm dLine controller mounting plate e r20 21 mm dLine controller mounting plate e r24 25 mm The milling profile varies depending on the mounting plate which is used For mounting plate dimensions see 8 BLU e Fitting Guide MOUNTING INSTRUCTIONS EKEY DLINE CABLE TRANSFER CX BLU E CU CX BLU E CU MP LIT FG BLU e ...

Page 9: ...nsfer cable to cover fixing screw The transfer unit connects to the power supply unit by the means of the frame cable this is the white cable that is provided in the transfer unit bag this cable locates on the frame as shown below and the cable runs back to the power supply unit See page 7 for transfer unit s milling details Pass white cable through pre drilled holes in frame as per drawings on Pa...

Page 10: ...lied these are reverse thread Push the blue connector on the cable into the blue receptor on the motor in the correct orientation 3 CONNECTION OF SEPARABLE CABLE FROM BAR HANDLE TO CABLE FOR CONTROL RELAY UNIT The separable cables have a tear drop alignment mark on both parts align these marks and push the two cables together and then screw the knurled sleeves together to ensure a tight fit of the...

Page 11: ...ular hole behind the wire to release the clasp that holds the wire in place 5 WIRING OF THE MOTOR CABLE TO THE MOTOR SOCKET ON THE CONTROL UNIT RELAY Three wires are required for this set up White Brown and Green the Yellow and Grey wire are not required so will require isolating Do not cut the ends of these wires as they will push straight into the sockets on the white plug White wire goes to soc...

Page 12: ...eutral to the N terminal Once the system is properly wired voltage can be applied 240v a blue light should be visible on the power supply unit and a blue light visible on the finger scanner at this point an audible click should be heard from the motor The system is now in test mode placing a finger on the scanner should activate a cycle on the motor If the test fails check all wiring has been conn...

Page 13: ...nly activated if your ekey dLine system is connected to the internet A stable password protected 2 4 GHz WLAN network with WPA PSK2 encryption is essential in the wireless range of the front door You can also set up activation via a hotspot on your mobile device The procedure for setting up the hotspot can be found in the operating instructions for your mobile device For security reasons the biony...

Page 14: ...ep is very important DO NOT IGNORE If you activate the iCloud backup function or the Google drive backup function the backup code will be saved in your iCloud or in your Google Drive account If you lose your iPhone or your Android smartphone or switch to a new one your ekey bionyx data is safe and can be restored at any time using your iCloud or Google Drive account WHAT IS THE SYSTEM BACKUP NEEDE...

Page 15: ...n cleaning agents and disinfectants with less than 10 minutes of exposure Stainless Steel Renovation Kit DR121 removes tea stains surface rust contamination and on site dust and dirt without attacking the metal It is a combination of organic acids and surface active agents with a pH value of 3 It doesn t present a danger to the person using it or the environment It is free from abrasive particles ...

Page 16: ...different intervals in which they light up One blue illuminated LED segment and one blue flashing LED segment If the top left LED segment is continuously illuminated blue while the top right LED segment flashes blue the connection to the local network is being established Two blue illuminated segments and one blue flashing LED segment If both top LED segments are continuously illuminated blue whil...

Page 17: ...ntinuosly illuminated blue the ekey dLine fingerprint scanner is in its normal state of operation Four orange illuminated LED segments If all four LED segments are continuosly illuminated orange the selected finger can be stored Four green illuminated LED segments If all four LED segments are continuosly illuminated green an authorised finger has been recognised and the door opens USER INSTRUCTION...

Page 18: ... the ekey dLine fingerprint scanner and the ekey dLine control unit has been disrupted If the system does not run to normal proceed as follows 1 Disconnect the power supply 2 Wait at least 10 seconds 3 Restore the power supply The system should now return to normal If contrary to expectations no connection is established between the ekey dLine fingerprint scanner and the ekey dLine control unit co...

Page 19: ...top LED segments are illuminated blue and both bottom LED segments are illuminated red the matching of the finger has been interrupted This can be triggered by an incorrect finger position fingertip or by interference on the sensor water coarse contaminants Make sure you hold your fingers correctly and make sure that there are no foreign objects on the fingerprint scanner Two green illuminated LED...

Page 20: ...USER INSTRUCTIONS BLU E BIOMETRIC PULL HANDLE LIT FG BLU e QR CODES Wiring diagrams Customer training Mounting instructions dLine FAQs Data sheets Instructions for fitters 20 BLU e Fitting Guide ...

Page 21: ...21 www coastal group com FITTING GUIDE LIFESTYLE IMAGES LIT FG BLU e ...