ZENO
®
Weather Station Manual
Annex 2
820 First Avenue South, Seattle, WA 98134, USA Tel: +1 (800) 488-8291 / +1 (206) 682-6048 Fax: +1 (206) 682-5658 www.CoastalEnvironmental.com
Procedure to Set the ZENO
®
3200 Data Output
for Polling
1) You will need to turn off the Data Collector for INTERCEPT
®
in order to use HyperTerminal
on the same comport. On your computer, go to
Start\Control Panel\Administrative Tools
and
open
Services
. Locate
CES INTERCEPT
in the list. Right click on it and choose
Stop.
Once
the service has stopped, proceed with the next step.
2) Set up a HyperTerminal window in order to communicate with the Base Station as follows:
A) Locate and select the HyperTerminal program in Start/Programs/
Accessories/Communications/HyperTerminal.
B) If HyperTerminal asks you to make it your default terminal program
click “Yes”.
C) In the “Connection Description” window type any name for the connection
(such as “Wthrpk”) and click “OK”.
D) In the “Connect To” window go to “Connect using” and select
Com 3 on your computer. Click “OK”
E) In the COM X Properties window the select the port settings as follows:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Click “Apply” then “OK”. Your HyperTerminal window should now be connected to the
selected com port on your computer. The lower left hand side of the window should
show “Connected” with a timer counting up.
3) Type
u<enter>
to access the ZENO
®
User Menu. Your screen should now show:
USER MENU
(C) Communications Menu
(T) Test Menu
(F) System Functions Menu
(Z) Zeno Program Menu
(S) Sample Period Menu
(Q) Quit
(D) Data Retrieval Menu
(H) Help
4) Type
s<enter>
for the Data Retrieval Menu
SAMPLE PERIOD MENU
(Cn/m) Change Item n To Value m
(Q) Quit
(E) Save Parameters To EEPROM
(H) Help
(U) User Menu
25