ZENO
®
Weather Station Manual
Annex 7
820 First Avenue South, Seattle, WA 98134, USA Tel: +1 (800) 488-8291 / +1 (206) 682-6048 Fax: +1 (206) 682-5658 www.CoastalEnvironmental.com
Procedure to Enter Elevation Offset for
Pressure in a ZENO
®
3200 System
IF INTERCEPT
®
1.17.33 or above IS RUNNING ON THE COMPUTER, TURN IT OFF AND
STOP THE SERVICE (Start/Settings/ControlPanel/AdministrativeTools/Services. Right Click
on CES INTERCEPT and choose Stop).
1) Set up a HyperTerminal window in order to communicate with the ZENO
®
3200 as follows:
A) Locate and select the HyperTerminal program in Start/Programs/
Accessories/Communications/HyperTerminal.
B) If HyperTerminal asks you to make it your default terminal program
click “Yes”.
C) In the “Connection Description” window type any name for the connection
(such as “Wthrpk”) and click “OK”.
D) In the “Connect To” window go to “Connect using” and select an open
comport on your computer (usually COM 1). Click “OK”
E) In the COM X Properties window the select the port settings as follows:
Bits per second: 9600
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Click “Apply” then “OK”. Your HyperTerminal window should now be connected to the
selected com port on your computer. T he lower left hand side of the window should
show “Connected” with a timer counting up.
2) Connect the black crossover cable to the DB9 port on the ZENO
®
3200 (unless you already
have a direct connection). Connect DB9 connector to serial com port on computer.
3) Apply power to the ZENO
®
. O n your HyperTerminal screen you should see a boot up
message similar to the following (if the ZENO
®
is already running you will not see the boot-up
message):
Watchdog Reset
Please wait.../
ZENO-3200 using ZENOSOFT V2.02 Sep 10 2002 11:29:41 CS B97B
(C)opyright 1995-2002, Coastal Environmental Systems, Seattle, WA, USA.
System Time = 07/03/02 17:25:02
Initializing Zeno 3200 .../
ZENO
®
3200 is Data Sampling. Type 'U'<enter> to access the User Interface
41