Instruction Manual

Safety Precautions

WEAR:

 

Protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all chemicals, or 
filling or emptying equipment.

ALWAYS:

 

Observe safety and handling instructions of the chemical manufacturer.

 

Direct discharge away from you or other persons or into approved containers.

 

Dispense cleaners and chemicals in accordance with manufacturer’s instructions. Exercise CAUTION when maintaining your 
equipment.

 

Reassemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.

KEEP:

 

Equipment clean to maintain proper operation.

ATTACH:

 

Only to water tap outlets (25 PSI Minimum, 85 PSI Maximum and Maximum water temperature 120°F).

NOTE:

 

If the unit is used to fill a sink or the discharge hose can be placed into a sink, the unit must be mounted so that the bottom of the 
cabinet is above the overflow rim of the sink.

Introduction

Installation and Operation

Installation

1.  Find suitable place close to a water source for dispenser. Remove wall bracket from packaging, place level on wall and mark (3) mounting 

holes. Drill (3) 5/16" holes and install anchors in wall. Secure wall bracket to wall with screws and washers provided.

Package Contents

1) ExpressMix

 Wall Mount Dispenser 

2)  Wall Bracket
3)  Mounting Hardware

4)  Drip Tray
5) Keys

Tools Needed 

1)  Drill and 5/16" Drill Bit
2) Screwdriver 

3) Level
4) Hammer

2.  Place the dispenser onto the wall bracket aligning the tabs with the slots in the top of the dispenser. Also ensure the central snap on top of 

the wall bracket engages the dispenser.

WARNING!

 This chemical proportioning system should be installed and serviced in accordance with these instructions. 

The customer is responsible for confirming that installation and service are performed in compliance with all national 
and local plumbing, building and other applicable laws, codes and ordinances. Staples is not responsible for improper 
installation nor product failure due to improper installation.

Screws, Washers, and

Drywall Anchors

Summary of Contents for ExpressMix

Page 1: ...ove the overflow rim of the sink Introduction Installation and Operation Installation 1 Find suitable place close to a water source for dispenser Remove wall bracket from packaging place level on wall...

Page 2: ...upply Minimum 25 PSI pressure with water running is required for proper operation Maximum pressure 85 PSI Maximum water temperature 120 F 6 Screw the orange cap tightly onto the top of the chemical bo...

Page 3: ...net 11 HYD10075980 Valve parts kit a diaphragm b armature c spring d valve bonnet Parts Diagram 12 HYD10088888 2 5 GPM eductor assembly 13 HYD10080957 Kit select valve replacement e support clip f O r...

Page 4: ...re of unit to turn off a Water valve parts dirty or defective Clean or replace with valve parts kit b Magnet doesn t fully return Make sure magnet moves freely c Push button stuck Remove button and cl...

Page 5: ...egadero Introducci n Instalaci n y operaci n Instalaci n 1 Encuentre un lugar adecuado cerca de un suministro de agua para el dosificador Retire el soporte para pared del empaque p ngalo nivelado en l...

Page 6: ...para tener un funcionamiento adecuado Presi n m xima 85 PSI Temperatura m xima del agua 120 F 6 Atornille la tapa naranja y apri tela bien sobre la parte superior de la botella de producto qu mico y d...

Page 7: ...v lvula a diafragma b armadura c resorte d cubrev lvula Diagrama de piezas 12 HYD10088888 conjunto de eductor de 2 5 GPM 13 HYD10080957 Juego reemplazo de v lvula seleccionada e clip de apoyo f anillo...

Page 8: ...unidad no se puede apagar a Las piezas de la v lvula de agua est n sucias L mpielas o reempl celas con el juego de piezas de v lvula o defectuosas b El im n no vuelve por completo Aseg rese de que el...