background image

 

Page 2 of 5 

 

www.cobhamsatcom.com 

Field replacement procedure –  
Doc. No.: 97-178838-A 

 

Replacing the part: 

1.

 

Open the service hatch, loosen the 8 screws.  
 
Do not use a power tool!  
 
Access the pedestal through the hatch.

 

 

2.

 

Power off the ADU (at the ADU power on/off 
switch at the antenna control module).

 

 

3.

 

Remove the feed horn with a suitably sized 
wrench. Apply the wrench close to the dish, see 
the flattened area. Turn anti-clockwise. 
 

Important:

 Handle the feed horn carefully 

and make sure that it does falls down and 
gets broken.

 

 

4.

 

Disconnect the cable from the RF pack to the 
plug marked BUC M&C (a).

 

5.

 

Remove the cable tie (b).

 

 

6.

 

Remove the TX coax cable connector. 

 

(a

(b) 

Reviews: